Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Supply voltage DC19.2 - 30V
Number of digital outputs0
Digital outputs configurableNo
Voltage type of supply voltageDC
Permitted voltage at input-3 - 5V
Digital inputs configurableNo
Number of digital inputs16
Type of voltage (input voltage)DC
Short-circuit protection, outputs availableNo
Number of interfaces PROFINET0
Input current at signal 10.0024mA
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet0
Type of digital outputNone
Number of HW-interfaces RS-4850
Number of HW-interfaces RS-4220
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Number of HW-interfaces other0
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Number of HW-interfaces Wireless0
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Supporting protocol for EtherCATNo
Number of HW-interfaces USB0
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusNo
With optical interfaceNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for LONNo
Supporting protocol for ASINo
Supporting protocol for SUCONETNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SERCOSNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Supporting protocol for other bus systemsYes
Radio standard GPRSNo
Supporting protocol for INTERBUS-SafetyNo
Radio standard GSMNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Radio standard BluetoothNo
Radio standard UMTSNo
Radio standard Wi-Fi 802.11No
System accessoryYes
Type of electric connectionOther
Degree of protection (IP)IP20
Fieldbus connection over separate bus coupler possibleYes
Wall mounting/direct mountingNo
IO link masterNo
Front built-in possibleNo
Rack-assembly possibleNo
Rail mounting possibleYes
Time delay at signal exchange0 - 0ms
Appendant operation agent (Ex ia)No
Performance level according to EN ISO 13849-1None
SIL according to IEC 61508None
Depth52.59mm
Height129.388068mm
Width53.6mm
Suitable for safety functionsNo
Explosion safety category for gasNone
Explosion safety category for dustNone
Appendant operation agent (Ex ib)No

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2701224 | AXL F DI16/4 XC 2F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Supply voltage DC

19.2 .. 30V

Number of digital outputs

0

Digital outputs configurable

Voltage type of supply voltage

DC

Permitted voltage at input

-3 .. 5V

Digital inputs configurable

Number of digital inputs

16

Type of voltage (input voltage)

DC

Short-circuit protection, outputs available

Number of interfaces PROFINET

0

Input current at signal 1

0.0024mA

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

0

Type of digital output

None

Number of HW-interfaces RS-485

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

Number of HW-interfaces other

0

Supporting protocol for TCP/IP

Supporting protocol for CAN

Number of HW-interfaces Wireless

0

Supporting protocol for KNX

Supporting protocol for INTERBUS

Supporting protocol for EtherCAT

Number of HW-interfaces USB

0

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

With optical interface

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for LON

Supporting protocol for ASI

Supporting protocol for SUCONET

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for SERCOS

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Supporting protocol for other bus systems

Radio standard GPRS

Supporting protocol for INTERBUS-Safety

Radio standard GSM

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Radio standard Bluetooth

Radio standard UMTS

Radio standard Wi-Fi 802.11

System accessory

Type of electric connection

Other

Degree of protection (IP)

IP20

Fieldbus connection over separate bus coupler possible

Wall mounting/direct mounting

IO link master

Front built-in possible

Rack-assembly possible

Rail mounting possible

Time delay at signal exchange

0 .. 0ms

Appendant operation agent (Ex ia)

Performance level according to EN ISO 13849-1

None

SIL according to IEC 61508

None

Depth

52.59mm

Height

129.388068mm

Width

53.6mm

Suitable for safety functions

Explosion safety category for gas

None

Explosion safety category for dust

None

Appendant operation agent (Ex ib)