Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Voltage type of supply voltageDC
Type of voltage (input voltage)DC
Digital inputs configurableNo
Number of digital inputs8
Output current2A
Number of digital outputs4
Input current at signal 10.003mA
Type of digital outputNone
Permitted voltage at input0 - 5V
Digital outputs configurableNo
Permitted voltage at output24 - 24V
Number of HW-interfaces industrial Ethernet0
Number of interfaces PROFINET0
Number of HW-interfaces RS-2320
Short-circuit protection, outputs availableYes
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4850
Number of HW-interfaces RS-4220
Number of HW-interfaces parallel0
Number of HW-interfaces other0
Number of HW-interfaces USB0
Supporting protocol for EtherCATNo
Supporting protocol for TCP/IPNo
With optical interfaceNo
Number of HW-interfaces Wireless0
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for ASINo
Supporting protocol for ModbusNo
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for KNXNo
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFINET IONo
Supporting protocol for LONNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for DeviceNet SafetyNo
Radio standard Wi-Fi 802.11No
Radio standard GSMNo
Supporting protocol for other bus systemsYes
Radio standard GPRSNo
Radio standard UMTSNo
Radio standard BluetoothNo
System accessoryYes
IO link masterNo
Supporting protocol for SafetyBUS pNo
Fieldbus connection over separate bus coupler possibleYes
Rail mounting possibleNo
Degree of protection (IP)IP65/IP67
Front built-in possibleNo
Time delay at signal exchange0 - 0ms
Wall mounting/direct mountingNo
Rack-assembly possibleNo
Appendant operation agent (Ex ia)No
Explosion safety category for gasNone
SIL according to IEC 61508None
Appendant operation agent (Ex ib)No
Suitable for safety functionsNo
Explosion safety category for dustNone
Performance level according to EN ISO 13849-1None

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2701512 | AXL E PN DI8 DO4 2A M12 6P

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Voltage type of supply voltage

DC

Type of voltage (input voltage)

DC

Digital inputs configurable

Number of digital inputs

8

Output current

2A

Number of digital outputs

4

Input current at signal 1

0.003mA

Type of digital output

None

Permitted voltage at input

0 .. 5V

Digital outputs configurable

Permitted voltage at output

24 .. 24V

Number of HW-interfaces industrial Ethernet

0

Number of interfaces PROFINET

0

Number of HW-interfaces RS-232

0

Short-circuit protection, outputs available

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Number of HW-interfaces other

0

Number of HW-interfaces USB

0

Supporting protocol for EtherCAT

Supporting protocol for TCP/IP

With optical interface

Number of HW-interfaces Wireless

0

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Supporting protocol for KNX

Supporting protocol for Data-Highway

Supporting protocol for PROFINET IO

Supporting protocol for LON

Supporting protocol for SERCOS

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for DeviceNet Safety

Radio standard Wi-Fi 802.11

Radio standard GSM

Supporting protocol for other bus systems

Radio standard GPRS

Radio standard UMTS

Radio standard Bluetooth

System accessory

IO link master

Supporting protocol for SafetyBUS p

Fieldbus connection over separate bus coupler possible

Rail mounting possible

Degree of protection (IP)

IP65/IP67

Front built-in possible

Time delay at signal exchange

0 .. 0ms

Wall mounting/direct mounting

Rack-assembly possible

Appendant operation agent (Ex ia)

Explosion safety category for gas

None

SIL according to IEC 61508

None

Appendant operation agent (Ex ib)

Suitable for safety functions

Explosion safety category for dust

None

Performance level according to EN ISO 13849-1

None

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.