  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Type of digital outputNone
Voltage type of supply voltageDC
Short-circuit protection, outputs availableYes
Digital outputs configurableNo
Digital inputs configurableNo
Permitted voltage at input0 - 5V
Number of HW-interfaces RS-4220
Number of digital outputs16
Input current at signal 10.003mA
Output current0.5A
Number of HW-interfaces industrial Ethernet0
Number of interfaces PROFINET0
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Number of digital inputs16
Permitted voltage at output24 - 24V
Type of voltage (input voltage)DC
Number of HW-interfaces other2
Number of HW-interfaces USB0
Number of HW-interfaces Wireless0
Number of HW-interfaces parallel0
Supporting protocol for EtherCATNo
With optical interfaceNo
Supporting protocol for INTERBUSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for ASINo
Supporting protocol for DeviceNetNo
Supporting protocol for TCP/IPNo
Supporting protocol for KNXNo
Supporting protocol for Data-HighwayNo
Supporting protocol for CANNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for ModbusNo
Supporting protocol for LONNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFIBUSNo
Supporting protocol for EtherNet/IPNo
Radio standard BluetoothNo
Supporting protocol for PROFIsafeNo
Supporting protocol for DeviceNet SafetyNo
Radio standard GSMNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for AS-Interface Safety at WorkNo
Radio standard Wi-Fi 802.11No
Supporting protocol for INTERBUS-SafetyNo
Time delay at signal exchange0 - 0ms
Rack-assembly possibleNo
Rail mounting possibleNo
Supporting protocol for other bus systemsYes
Front built-in possibleNo
Wall mounting/direct mountingNo
IO link masterNo
Degree of protection (IP)IP65/IP67
Radio standard UMTSNo
Radio standard GPRSNo
Fieldbus connection over separate bus coupler possibleYes
System accessoryYes
Explosion safety category for gasNone
Appendant operation agent (Ex ib)No
SIL according to IEC 61508None
Explosion safety category for dustNone
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Suitable for safety functionsNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2701522 | AXL E EC DIO16 M12 6P

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Type of digital output

None

Voltage type of supply voltage

DC

Short-circuit protection, outputs available

Digital outputs configurable

Digital inputs configurable

Permitted voltage at input

0 .. 5V

Number of HW-interfaces RS-422

0

Number of digital outputs

16

Input current at signal 1

0.003mA

Output current

0.5A

Number of HW-interfaces industrial Ethernet

0

Number of interfaces PROFINET

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces serial TTY

0

Number of digital inputs

16

Permitted voltage at output

24 .. 24V

Type of voltage (input voltage)

DC

Number of HW-interfaces other

2

Number of HW-interfaces USB

0

Number of HW-interfaces Wireless

0

Number of HW-interfaces parallel

0

Supporting protocol for EtherCAT

With optical interface

Supporting protocol for INTERBUS

Supporting protocol for Foundation Fieldbus

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for TCP/IP

Supporting protocol for KNX

Supporting protocol for Data-Highway

Supporting protocol for CAN

Supporting protocol for SUCONET

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for Modbus

Supporting protocol for LON

Supporting protocol for SERCOS

Supporting protocol for PROFIBUS

Supporting protocol for EtherNet/IP

Radio standard Bluetooth

Supporting protocol for PROFIsafe

Supporting protocol for DeviceNet Safety

Radio standard GSM

Supporting protocol for SafetyBUS p

Supporting protocol for AS-Interface Safety at Work

Radio standard Wi-Fi 802.11

Supporting protocol for INTERBUS-Safety

Time delay at signal exchange

0 .. 0ms

Rack-assembly possible

Rail mounting possible

Supporting protocol for other bus systems

Front built-in possible

Wall mounting/direct mounting

IO link master

Degree of protection (IP)

IP65/IP67

Radio standard UMTS

Radio standard GPRS

Fieldbus connection over separate bus coupler possible

System accessory

Explosion safety category for gas

None

Appendant operation agent (Ex ib)

SIL according to IEC 61508

None

Explosion safety category for dust

None

Performance level according to EN ISO 13849-1

None

Appendant operation agent (Ex ia)

Suitable for safety functions

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.