Technical specifications

Number of digital outputs0
Input current at signal 10.003mA
Permitted voltage at input-0.3 - 5V
Type of voltage (input voltage)DC
Digital outputs configurableNo
Type of digital outputNone
Voltage type of supply voltageDC
Number of HW-interfaces industrial Ethernet0
Digital inputs configurableNo
Short-circuit protection, outputs availableNo
Number of HW-interfaces RS-2320
Number of digital inputs4
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Number of interfaces PROFINET0
Number of HW-interfaces parallel0
Number of HW-interfaces Wireless0
Number of HW-interfaces USB0
Supporting protocol for EtherCATNo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
With optical interfaceNo
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for KNXNo
Supporting protocol for LONNo
Supporting protocol for DeviceNetNo
Supporting protocol for PROFINET IONo
Supporting protocol for CANNo
Supporting protocol for ModbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for SERCOSNo
Number of HW-interfaces other4
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for other bus systemsYes
Radio standard Wi-Fi 802.11No
Supporting protocol for INTERBUS-SafetyNo
Radio standard BluetoothNo
Supporting protocol for SafetyBUS pNo
Radio standard GSMNo
IO link masterYes
System accessoryYes
Radio standard GPRSNo
Degree of protection (IP)IP65/IP67
Radio standard UMTSNo
Wall mounting/direct mountingNo
Fieldbus connection over separate bus coupler possibleYes
Rail mounting possibleNo
Front built-in possibleNo
Time delay at signal exchange0 - 0ms
Suitable for safety functionsNo
Rack-assembly possibleNo
SIL according to IEC 61508None
Appendant operation agent (Ex ia)No
Explosion safety category for gasNone
Explosion safety category for dustNone
Appendant operation agent (Ex ib)No
Performance level according to EN ISO 13849-1None

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2701524 | AXL E EC IOL8 DI4 M12 6P

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Number of digital outputs

0

Input current at signal 1

0.003mA

Permitted voltage at input

-0.3 .. 5V

Type of voltage (input voltage)

DC

Digital outputs configurable

Type of digital output

None

Voltage type of supply voltage

DC

Number of HW-interfaces industrial Ethernet

0

Digital inputs configurable

Short-circuit protection, outputs available

Number of HW-interfaces RS-232

0

Number of digital inputs

4

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces serial TTY

0

Number of interfaces PROFINET

0

Number of HW-interfaces parallel

0

Number of HW-interfaces Wireless

0

Number of HW-interfaces USB

0

Supporting protocol for EtherCAT

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for ASI

With optical interface

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Supporting protocol for KNX

Supporting protocol for LON

Supporting protocol for DeviceNet

Supporting protocol for PROFINET IO

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for SERCOS

Number of HW-interfaces other

4

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for other bus systems

Radio standard Wi-Fi 802.11

Supporting protocol for INTERBUS-Safety

Radio standard Bluetooth

Supporting protocol for SafetyBUS p

Radio standard GSM

IO link master

System accessory

Radio standard GPRS

Degree of protection (IP)

IP65/IP67

Radio standard UMTS

Wall mounting/direct mounting

Fieldbus connection over separate bus coupler possible

Rail mounting possible

Front built-in possible

Time delay at signal exchange

0 .. 0ms

Suitable for safety functions

Rack-assembly possible

SIL according to IEC 61508

None

Appendant operation agent (Ex ia)

Explosion safety category for gas

None

Explosion safety category for dust

None

Appendant operation agent (Ex ib)

Performance level according to EN ISO 13849-1

None