Technical specifications

Supply voltage DC19.2 - 30V
Voltage type of supply voltageDC
Input, currentYes
Input, resistance thermometerNo
Resolution of the analogue inputs16Bit
Input, resistorNo
Input signal, configurableYes
Input, thermocoupleNo
Output signal configurableNo
Input, voltageNo
Output, currentNo
Number of interfaces PROFINET0
Analogue outputs configurableNo
Output, voltageNo
Number of analogue outputs0
Number of HW-interfaces industrial Ethernet0
Analogue inputs configurableYes
Number of analogue inputs4
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4220
Number of HW-interfaces Wireless0
Number of HW-interfaces serial TTY0
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Number of HW-interfaces USB0
Number of HW-interfaces RS-2320
Supporting protocol for KNXNo
Number of HW-interfaces other0
Supporting protocol for ModbusNo
Supporting protocol for EtherCATNo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFINET IONo
Supporting protocol for Data-HighwayNo
Supporting protocol for LONNo
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for CANNo
Number of HW-interfaces RS-4850
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Supporting protocol for AS-Interface Safety at WorkNo
Radio standard BluetoothNo
Supporting protocol for INTERBUS-SafetyNo
Radio standard GPRSNo
Supporting protocol for SERCOSNo
Supporting protocol for SafetyBUS pNo
Radio standard GSMNo
System accessoryYes
Supporting protocol for other bus systemsYes
IO link masterNo
Radio standard UMTSNo
Type of electric connectionOther
Supporting protocol for DeviceNet SafetyNo
Fieldbus connection over separate bus coupler possibleYes
Radio standard Wi-Fi 802.11No
Degree of protection (IP)IP20
Supporting protocol for Foundation FieldbusNo
Rail mounting possibleYes
Rack-assembly possibleNo
Front built-in possibleNo
Wall mounting/direct mountingYes
Explosion safety category for dustNone
Height125.893334mm
Appendant operation agent (Ex ib)No
Appendant operation agent (Ex ia)No
Depth52.649984mm
Width35mm
Suitable for safety functionsNo
Performance level according to EN ISO 13849-1None
Explosion safety category for gasNone

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2702007 | AXL F AI4 I XC 1H

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Supply voltage DC

19.2 .. 30V

Voltage type of supply voltage

DC

Input, current

Input, resistance thermometer

Resolution of the analogue inputs

16Bit

Input, resistor

Input signal, configurable

Input, thermocouple

Output signal configurable

Input, voltage

Output, current

Number of interfaces PROFINET

0

Analogue outputs configurable

Output, voltage

Number of analogue outputs

0

Number of HW-interfaces industrial Ethernet

0

Analogue inputs configurable

Number of analogue inputs

4

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces Wireless

0

Number of HW-interfaces serial TTY

0

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Number of HW-interfaces USB

0

Number of HW-interfaces RS-232

0

Supporting protocol for KNX

Number of HW-interfaces other

0

Supporting protocol for Modbus

Supporting protocol for EtherCAT

Supporting protocol for TCP/IP

Supporting protocol for PROFINET IO

Supporting protocol for Data-Highway

Supporting protocol for LON

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Supporting protocol for CAN

Number of HW-interfaces RS-485

0

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Supporting protocol for AS-Interface Safety at Work

Radio standard Bluetooth

Supporting protocol for INTERBUS-Safety

Radio standard GPRS

Supporting protocol for SERCOS

Supporting protocol for SafetyBUS p

Radio standard GSM

System accessory

Supporting protocol for other bus systems

IO link master

Radio standard UMTS

Type of electric connection

Other

Supporting protocol for DeviceNet Safety

Fieldbus connection over separate bus coupler possible

Radio standard Wi-Fi 802.11

Degree of protection (IP)

IP20

Supporting protocol for Foundation Fieldbus

Rail mounting possible

Rack-assembly possible

Front built-in possible

Wall mounting/direct mounting

Explosion safety category for dust

None

Height

125.893334mm

Appendant operation agent (Ex ib)

Appendant operation agent (Ex ia)

Depth

52.649984mm

Width

35mm

Suitable for safety functions

Performance level according to EN ISO 13849-1

None

Explosion safety category for gas

None

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.