Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Digital inputs configurableNo
Supply voltage DC19.2 - 30V
Voltage type of supply voltageDC
Number of digital outputs8
Number of digital inputs16
Digital outputs configurableNo
Permitted voltage at input-3 - 5V
Output current2A
Short-circuit protection, outputs availableYes
Input current at signal 10.0024mA
Type of voltage (input voltage)DC
Permitted voltage at output24 - 24V
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-2320
Type of digital outputOther
Number of HW-interfaces RS-4850
Number of HW-interfaces RS-4220
Number of interfaces PROFINET0
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Number of HW-interfaces serial TTY0
Number of HW-interfaces other0
Number of HW-interfaces Wireless0
Supporting protocol for CANNo
Supporting protocol for EtherCATNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFINET IONo
Supporting protocol for LONNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for DeviceNetNo
Supporting protocol for SERCOSNo
Supporting protocol for KNXNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SUCONETNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for other bus systemsYes
Radio standard BluetoothNo
Radio standard GSMNo
Radio standard Wi-Fi 802.11No
System accessoryYes
IO link masterNo
Radio standard UMTSNo
Radio standard GPRSNo
Degree of protection (IP)IP20
Supporting protocol for SafetyBUS pNo
Type of electric connectionOther
Time delay at signal exchange0 - 0ms
Rail mounting possibleYes
Wall mounting/direct mountingNo
Fieldbus connection over separate bus coupler possibleYes
Rack-assembly possibleNo
Front built-in possibleNo
Suitable for safety functionsNo
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ib)No
Appendant operation agent (Ex ia)No
Depth52.589984mm
Explosion safety category for dustNone
Height129.387027mm
Explosion safety category for gasNone
Width35mm

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2702291 | AXL F DI16/1 DO8/2-2A 2H

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Digital inputs configurable

Supply voltage DC

19.2 .. 30V

Voltage type of supply voltage

DC

Number of digital outputs

8

Number of digital inputs

16

Digital outputs configurable

Permitted voltage at input

-3 .. 5V

Output current

2A

Short-circuit protection, outputs available

Input current at signal 1

0.0024mA

Type of voltage (input voltage)

DC

Permitted voltage at output

24 .. 24V

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-232

0

Type of digital output

Other

Number of HW-interfaces RS-485

0

Number of HW-interfaces RS-422

0

Number of interfaces PROFINET

0

Number of HW-interfaces USB

0

Number of HW-interfaces parallel

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces other

0

Number of HW-interfaces Wireless

0

Supporting protocol for CAN

Supporting protocol for EtherCAT

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for INTERBUS

With optical interface

Supporting protocol for TCP/IP

Supporting protocol for PROFINET IO

Supporting protocol for LON

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Supporting protocol for KNX

Supporting protocol for PROFINET CBA

Supporting protocol for SUCONET

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for other bus systems

Radio standard Bluetooth

Radio standard GSM

Radio standard Wi-Fi 802.11

System accessory

IO link master

Radio standard UMTS

Radio standard GPRS

Degree of protection (IP)

IP20

Supporting protocol for SafetyBUS p

Type of electric connection

Other

Time delay at signal exchange

0 .. 0ms

Rail mounting possible

Wall mounting/direct mounting

Fieldbus connection over separate bus coupler possible

Rack-assembly possible

Front built-in possible

Suitable for safety functions

SIL according to IEC 61508

None

Performance level according to EN ISO 13849-1

None

Appendant operation agent (Ex ib)

Appendant operation agent (Ex ia)

Depth

52.589984mm

Explosion safety category for dust

None

Height

129.387027mm

Explosion safety category for gas

None

Width

35mm

Related products