Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Input, resistance thermometerYes
Input, thermocoupleNo
Output signal configurableNo
Input signal, configurableNo
Output, voltageNo
Number of analogue outputs0
Input, resistorYes
Number of analogue inputs0
Input, voltageNo
Number of interfaces PROFINET0
Analogue outputs configurableNo
Number of HW-interfaces industrial Ethernet0
Resolution of the analogue inputs16Bit
Supply voltage DC19.2 - 30V
Voltage type of supply voltageDC
Input, currentNo
Analogue inputs configurableNo
Output, currentNo
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Supporting protocol for TCP/IPNo
Number of HW-interfaces other0
Supporting protocol for EtherCATNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for CANNo
Number of HW-interfaces parallel0
Supporting protocol for KNXNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Supporting protocol for DeviceNetNo
Supporting protocol for PROFINET IONo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Number of HW-interfaces Wireless0
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsYes
Radio standard BluetoothNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for EtherNet/IPNo
Radio standard Wi-Fi 802.11No
Radio standard GSMNo
Radio standard GPRSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
System accessoryYes
Degree of protection (IP)IP20
IO link masterNo
Radio standard UMTSNo
Type of electric connectionOther
Supporting protocol for SERCOSNo
Rail mounting possibleYes
Fieldbus connection over separate bus coupler possibleYes
Wall mounting/direct mountingYes
Appendant operation agent (Ex ia)No
Explosion safety category for gasNone
Width12.15mm
Explosion safety category for dustNone
Depth70.51mm
Appendant operation agent (Ex ib)No
Height138.44mm
Rack-assembly possibleNo
Suitable for safety functionsNo
Performance level according to EN ISO 13849-1None
Front built-in possibleNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2861328 | IB IL TEMP 2 RTD-PAC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Input, resistance thermometer

Input, thermocouple

Output signal configurable

Input signal, configurable

Output, voltage

Number of analogue outputs

0

Input, resistor

Number of analogue inputs

0

Input, voltage

Number of interfaces PROFINET

0

Analogue outputs configurable

Number of HW-interfaces industrial Ethernet

0

Resolution of the analogue inputs

16Bit

Supply voltage DC

19.2 .. 30V

Voltage type of supply voltage

DC

Input, current

Analogue inputs configurable

Output, current

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

0

Supporting protocol for TCP/IP

Number of HW-interfaces other

0

Supporting protocol for EtherCAT

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for CAN

Number of HW-interfaces parallel

0

Supporting protocol for KNX

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Supporting protocol for DeviceNet

Supporting protocol for PROFINET IO

Supporting protocol for SUCONET

Supporting protocol for LON

Number of HW-interfaces Wireless

0

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Radio standard Bluetooth

Supporting protocol for INTERBUS-Safety

Supporting protocol for EtherNet/IP

Radio standard Wi-Fi 802.11

Radio standard GSM

Radio standard GPRS

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

System accessory

Degree of protection (IP)

IP20

IO link master

Radio standard UMTS

Type of electric connection

Other

Supporting protocol for SERCOS

Rail mounting possible

Fieldbus connection over separate bus coupler possible

Wall mounting/direct mounting

Appendant operation agent (Ex ia)

Explosion safety category for gas

None

Width

12.15mm

Explosion safety category for dust

None

Depth

70.51mm

Appendant operation agent (Ex ib)

Height

138.44mm

Rack-assembly possible

Suitable for safety functions

Performance level according to EN ISO 13849-1

None

Front built-in possible

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.