Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Number of digital outputs32
Digital outputs configurableNo
Type of voltage (input voltage)DC
Output current0.5A
Number of digital inputs0
Number of HW-interfaces industrial Ethernet0
Supply voltage DC19.2 - 30V
Voltage type of supply voltageDC
Type of digital outputOther
Number of interfaces PROFINET0
Digital inputs configurableNo
Permitted voltage at output24 - 24V
Short-circuit protection, outputs availableYes
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4220
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4850
Number of HW-interfaces Wireless0
Number of HW-interfaces USB0
Supporting protocol for PROFIBUSNo
Supporting protocol for EtherCATNo
Supporting protocol for LONNo
Supporting protocol for KNXNo
Supporting protocol for SUCONETNo
With optical interfaceNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNetNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for TCP/IPNo
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFINET CBANo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
Number of HW-interfaces other0
Supporting protocol for ASINo
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET IONo
Supporting protocol for CANNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for other bus systemsYes
Radio standard BluetoothNo
Radio standard Wi-Fi 802.11No
Supporting protocol for PROFIsafeNo
System accessoryYes
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP20
IO link masterNo
Radio standard GSMNo
Radio standard UMTSNo
Radio standard GPRSNo
Fieldbus connection over separate bus coupler possibleYes
Front built-in possibleNo
Suitable for safety functionsNo
Rack-assembly possibleNo
Supporting protocol for SafetyBUS pNo
Wall mounting/direct mountingNo
Time delay at signal exchange0 - 0ms
Rail mounting possibleYes
Explosion safety category for dustNone
Width48.6mm
Explosion safety category for gasNone
Depth71.44238mm
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Height120.110773mm
Appendant operation agent (Ex ib)No
Appendant operation agent (Ex ia)No

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2878340 | IB IL 24 DO 32/HD-NPN-PAC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Number of digital outputs

32

Digital outputs configurable

Type of voltage (input voltage)

DC

Output current

0.5A

Number of digital inputs

0

Number of HW-interfaces industrial Ethernet

0

Supply voltage DC

19.2 .. 30V

Voltage type of supply voltage

DC

Type of digital output

Other

Number of interfaces PROFINET

0

Digital inputs configurable

Permitted voltage at output

24 .. 24V

Short-circuit protection, outputs available

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces Wireless

0

Number of HW-interfaces USB

0

Supporting protocol for PROFIBUS

Supporting protocol for EtherCAT

Supporting protocol for LON

Supporting protocol for KNX

Supporting protocol for SUCONET

With optical interface

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet

Supporting protocol for EtherNet/IP

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

Supporting protocol for PROFINET CBA

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Number of HW-interfaces other

0

Supporting protocol for ASI

Supporting protocol for SERCOS

Supporting protocol for PROFINET IO

Supporting protocol for CAN

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for other bus systems

Radio standard Bluetooth

Radio standard Wi-Fi 802.11

Supporting protocol for PROFIsafe

System accessory

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP20

IO link master

Radio standard GSM

Radio standard UMTS

Radio standard GPRS

Fieldbus connection over separate bus coupler possible

Front built-in possible

Suitable for safety functions

Rack-assembly possible

Supporting protocol for SafetyBUS p

Wall mounting/direct mounting

Time delay at signal exchange

0 .. 0ms

Rail mounting possible

Explosion safety category for dust

None

Width

48.6mm

Explosion safety category for gas

None

Depth

71.44238mm

SIL according to IEC 61508

None

Performance level according to EN ISO 13849-1

None

Height

120.110773mm

Appendant operation agent (Ex ib)

Appendant operation agent (Ex ia)