Technical specifications

Supply voltage DC19.2 - 30V
Input, currentYes
Input signal, configurableYes
Output, currentNo
Input, thermocoupleNo
Input, resistance thermometerNo
Resolution of the analogue inputs16Bit
Number of HW-interfaces industrial Ethernet0
Number of analogue outputs0
Output signal configurableNo
Analogue outputs configurableNo
Voltage type of supply voltageDC
Number of interfaces PROFINET0
Input, voltageYes
Analogue inputs configurableYes
Input, resistorNo
Output, voltageNo
Number of analogue inputs4
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Supporting protocol for PROFIBUSNo
Number of HW-interfaces RS-4220
Supporting protocol for CANNo
Number of HW-interfaces RS-2320
Supporting protocol for ASINo
Number of HW-interfaces Wireless0
Supporting protocol for ModbusNo
Supporting protocol for TCP/IPNo
Number of HW-interfaces other0
Supporting protocol for DeviceNetNo
Supporting protocol for KNXNo
Supporting protocol for EtherCATNo
Supporting protocol for PROFINET IONo
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Supporting protocol for INTERBUSNo
Supporting protocol for SERCOSNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET CBANo
Radio standard GPRSNo
System accessoryYes
Radio standard UMTSNo
Radio standard BluetoothNo
Supporting protocol for PROFIsafeNo
Supporting protocol for other bus systemsYes
Degree of protection (IP)IP20
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Radio standard GSMNo
Type of electric connectionOther
Supporting protocol for SafetyBUS pNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for INTERBUS-SafetyNo
Fieldbus connection over separate bus coupler possibleYes
IO link masterNo
Rail mounting possibleYes
Radio standard Wi-Fi 802.11No
Appendant operation agent (Ex ib)No
Explosion safety category for gasNone
Depth70.51mm
Front built-in possibleNo
Rack-assembly possibleNo
Explosion safety category for dustNone
Suitable for safety functionsNo
Performance level according to EN ISO 13849-1None
Height136.04mm
Appendant operation agent (Ex ia)No
Width48.6mm
Wall mounting/direct mountingYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2878641 | IB IL AI 4/EF-2MBD-PAC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue I/O module
  • 1 KOM
  • PHOENIX

Technical specifications

Supply voltage DC

19.2 .. 30V

Input, current

Input signal, configurable

Output, current

Input, thermocouple

Input, resistance thermometer

Resolution of the analogue inputs

16Bit

Number of HW-interfaces industrial Ethernet

0

Number of analogue outputs

0

Output signal configurable

Analogue outputs configurable

Voltage type of supply voltage

DC

Number of interfaces PROFINET

0

Input, voltage

Analogue inputs configurable

Input, resistor

Output, voltage

Number of analogue inputs

4

Number of HW-interfaces parallel

0

Number of HW-interfaces USB

0

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-422

0

Supporting protocol for CAN

Number of HW-interfaces RS-232

0

Supporting protocol for ASI

Number of HW-interfaces Wireless

0

Supporting protocol for Modbus

Supporting protocol for TCP/IP

Number of HW-interfaces other

0

Supporting protocol for DeviceNet

Supporting protocol for KNX

Supporting protocol for EtherCAT

Supporting protocol for PROFINET IO

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for LON

Number of HW-interfaces RS-485

0

Number of HW-interfaces serial TTY

0

Supporting protocol for INTERBUS

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Radio standard GPRS

System accessory

Radio standard UMTS

Radio standard Bluetooth

Supporting protocol for PROFIsafe

Supporting protocol for other bus systems

Degree of protection (IP)

IP20

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Radio standard GSM

Type of electric connection

Other

Supporting protocol for SafetyBUS p

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for INTERBUS-Safety

Fieldbus connection over separate bus coupler possible

IO link master

Rail mounting possible

Radio standard Wi-Fi 802.11

Appendant operation agent (Ex ib)

Explosion safety category for gas

None

Depth

70.51mm

Front built-in possible

Rack-assembly possible

Explosion safety category for dust

None

Suitable for safety functions

Performance level according to EN ISO 13849-1

None

Height

136.04mm

Appendant operation agent (Ex ia)

Width

48.6mm

Wall mounting/direct mounting