Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • ABB

Technical specifications

Height223mm
With control elementYes
Number of analogue inputs2
Number of analogue outputs2
Width73mm
Supporting protocol for LONNo
Number of digital inputs6
Number of digital outputs3
Depth208mm
With optical interfaceNo
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces parallel0
Supporting protocol for TCP/IPYes
Number of HW-interfaces serial TTY0
Number of HW-interfaces other2
Number of HW-interfaces RS-4220
Number of HW-interfaces USB1
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4851
Supporting protocol for other bus systemsYes
Supporting protocol for CANYes
Supporting protocol for ModbusYes
Type of converterU converter
Mains voltage380 - 480V
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetYes
Supporting protocol for INTERBUS-SafetyNo
4-quadrant operation possibleNo
Supporting protocol for SERCOSNo
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Number of interfaces PROFINET0
Degree of protection (IP)IP20
Supporting protocol for PROFIBUSYes
With PC connectionYes
Supporting protocol for ASINo
Mains frequency50/60 Hz
Integrated breaking resistanceNo
Number of phases input3
Application in industrial area permittedYes
Application in domestic- and commercial area permittedYes
Max. output frequency500Hz
Number of phases output3
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyYes
Relative symmetric net frequency tolerance5%
Supporting protocol for BACnetNo
Supporting protocol for PROFINET CBANo
Relative symmetric net voltage tolerance10%
Supporting protocol for Foundation FieldbusNo
Max. output at linear load at rated output voltage1.5kW
Nominal output current I2N4A
Max. output at quadratic load at rated output voltage1.5kW
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IOYes
Max. output voltage480V
Degree of protection (NEMA)Other
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ACS480-04-04A1-4 PN: 1,5kW, IN: 4A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • ABB

Technical specifications

Height

223mm

With control element

Number of analogue inputs

2

Number of analogue outputs

2

Width

73mm

Supporting protocol for LON

Number of digital inputs

6

Number of digital outputs

3

Depth

208mm

With optical interface

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces parallel

0

Supporting protocol for TCP/IP

Number of HW-interfaces serial TTY

0

Number of HW-interfaces other

2

Number of HW-interfaces RS-422

0

Number of HW-interfaces USB

1

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-485

1

Supporting protocol for other bus systems

Supporting protocol for CAN

Supporting protocol for Modbus

Type of converter

U converter

Mains voltage

380 .. 480V

Supporting protocol for SUCONET

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS-Safety

4-quadrant operation possible

Supporting protocol for SERCOS

Supporting protocol for KNX

Supporting protocol for INTERBUS

Number of interfaces PROFINET

0

Degree of protection (IP)

IP20

Supporting protocol for PROFIBUS

With PC connection

Supporting protocol for ASI

Mains frequency

50/60 Hz

Integrated breaking resistance

Number of phases input

3

Application in industrial area permitted

Application in domestic- and commercial area permitted

Max. output frequency

500Hz

Number of phases output

3

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Relative symmetric net frequency tolerance

5%

Supporting protocol for BACnet

Supporting protocol for PROFINET CBA

Relative symmetric net voltage tolerance

10%

Supporting protocol for Foundation Fieldbus

Max. output at linear load at rated output voltage

1.5kW

Nominal output current I2N

4A

Max. output at quadratic load at rated output voltage

1.5kW

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Max. output voltage

480V

Degree of protection (NEMA)

Other

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.