Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width250mm
Number of HW-interfaces industrial Ethernet0
Number of digital outputs3
Depth200mm
Number of HW-interfaces serial TTY0
Number of analogue inputs3
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Number of HW-interfaces other1
Number of analogue outputs1
With optical interfaceNo
Number of HW-interfaces USB0
Height340mm
Number of HW-interfaces parallel0
Supporting protocol for TCP/IPYes
Number of digital inputs7
Supporting protocol for LONNo
With control elementYes
Supporting protocol for CANYes
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSYes
Supporting protocol for ASINo
With PC connectionYes
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetYes
Degree of protection (IP)IP66
Supporting protocol for INTERBUS-SafetyNo
Mains voltage380 - 500V
Supporting protocol for SERCOSNo
Supporting protocol for ModbusYes
Mains frequency50/60 Hz
Supporting protocol for Data-HighwayNo
Supporting protocol for other bus systemsYes
Supporting protocol for KNXNo
Number of phases input3
Number of phases output3
Max. output frequency599Hz
Relative symmetric net frequency tolerance5%
Relative symmetric net voltage tolerance10%
Max. output at linear load at rated output voltage0.37kW
Integrated breaking resistanceYes
Type of converterU converter
Max. output at quadratic load at rated output voltage0.37kW
Application in industrial area permittedYes
4-quadrant operation possibleYes
Number of interfaces PROFINET0
Application in domestic- and commercial area permittedNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Max. output voltage500V
Degree of protection (NEMA)4X
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IOYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for BACnetNo
Nominal output current I2N1.5A
Supporting protocol for AS-Interface Safety at WorkNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV320U04N4W

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

250mm

Number of HW-interfaces industrial Ethernet

0

Number of digital outputs

3

Depth

200mm

Number of HW-interfaces serial TTY

0

Number of analogue inputs

3

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces other

1

Number of analogue outputs

1

With optical interface

Number of HW-interfaces USB

0

Height

340mm

Number of HW-interfaces parallel

0

Supporting protocol for TCP/IP

Number of digital inputs

7

Supporting protocol for LON

With control element

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for ASI

With PC connection

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Degree of protection (IP)

IP66

Supporting protocol for INTERBUS-Safety

Mains voltage

380 .. 500V

Supporting protocol for SERCOS

Supporting protocol for Modbus

Mains frequency

50/60 Hz

Supporting protocol for Data-Highway

Supporting protocol for other bus systems

Supporting protocol for KNX

Number of phases input

3

Number of phases output

3

Max. output frequency

599Hz

Relative symmetric net frequency tolerance

5%

Relative symmetric net voltage tolerance

10%

Max. output at linear load at rated output voltage

0.37kW

Integrated breaking resistance

Type of converter

U converter

Max. output at quadratic load at rated output voltage

0.37kW

Application in industrial area permitted

4-quadrant operation possible

Number of interfaces PROFINET

0

Application in domestic- and commercial area permitted

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Max. output voltage

500V

Degree of protection (NEMA)

4X

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for BACnet

Nominal output current I2N

1.5A

Supporting protocol for AS-Interface Safety at Work

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.