Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth200mm
Number of analogue outputs1
Width250mm
Number of HW-interfaces industrial Ethernet0
Number of digital inputs7
Number of HW-interfaces RS-2320
Number of digital outputs3
Number of analogue inputs3
Height340mm
With control elementYes
Supporting protocol for LONNo
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Number of HW-interfaces parallel0
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
With optical interfaceNo
Supporting protocol for PROFIBUSYes
Number of HW-interfaces other1
Supporting protocol for TCP/IPYes
Supporting protocol for ModbusYes
Supporting protocol for CANYes
4-quadrant operation possibleYes
Number of phases output3
Mains frequency50/60 Hz
Mains voltage380 - 500V
Type of converterU converter
Supporting protocol for KNXNo
Supporting protocol for ASINo
Integrated breaking resistanceYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SUCONETNo
Number of phases input3
With PC connectionYes
Number of interfaces PROFINET0
Supporting protocol for other bus systemsYes
Supporting protocol for INTERBUSNo
Degree of protection (IP)IP65
Supporting protocol for SERCOSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetYes
Supporting protocol for EtherNet/IPYes
Max. output frequency599Hz
Max. output at linear load at rated output voltage0.37kW
Application in industrial area permittedYes
Relative symmetric net frequency tolerance5%
Nominal output current I2N1.5A
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Degree of protection (NEMA)12
Supporting protocol for PROFINET IOYes
Max. output voltage500V
Max. output at quadratic load at rated output voltage0.37kW
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetNo
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net voltage tolerance10%
Application in domestic- and commercial area permittedNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV320U04N4WS | Frek. Pret. ATV320 0,37KW 400V 3PH Vario

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth

200mm

Number of analogue outputs

1

Width

250mm

Number of HW-interfaces industrial Ethernet

0

Number of digital inputs

7

Number of HW-interfaces RS-232

0

Number of digital outputs

3

Number of analogue inputs

3

Height

340mm

With control element

Supporting protocol for LON

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces parallel

0

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

With optical interface

Supporting protocol for PROFIBUS

Number of HW-interfaces other

1

Supporting protocol for TCP/IP

Supporting protocol for Modbus

Supporting protocol for CAN

4-quadrant operation possible

Number of phases output

3

Mains frequency

50/60 Hz

Mains voltage

380 .. 500V

Type of converter

U converter

Supporting protocol for KNX

Supporting protocol for ASI

Integrated breaking resistance

Supporting protocol for INTERBUS-Safety

Supporting protocol for SUCONET

Number of phases input

3

With PC connection

Number of interfaces PROFINET

0

Supporting protocol for other bus systems

Supporting protocol for INTERBUS

Degree of protection (IP)

IP65

Supporting protocol for SERCOS

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for EtherNet/IP

Max. output frequency

599Hz

Max. output at linear load at rated output voltage

0.37kW

Application in industrial area permitted

Relative symmetric net frequency tolerance

5%

Nominal output current I2N

1.5A

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Degree of protection (NEMA)

12

Supporting protocol for PROFINET IO

Max. output voltage

500V

Max. output at quadratic load at rated output voltage

0.37kW

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net voltage tolerance

10%

Application in domestic- and commercial area permitted