Aleta.hr
Announcement

Registration is currently available to business customers only (B2B).

Main Product Image

ATV320U07N4W | Frek. Pret. ATV320 0,75KW 400V 3PH IP66

Code: 1852569

ManufacturerSchneider Electric
Catalog numberATV320U07N4W
TypeATV320U07N4W
Category-
EAN code3606489548483

Details

  • •Low-voltage switchgear and control gear (automation)
  • •Frequency converter =< 1 kV
  • •Minimum order quantity: 1 pcs
  • •SCHNEIDER

Technical specifications

Depth200mm
Width250mm
Height340mm
Number of digital outputs3
With control elementYes
Number of digital inputs7
Number of analogue outputs1
Number of HW-interfaces RS-4220
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Supporting protocol for LONNo
Number of analogue inputs3
Supporting protocol for PROFIBUSYes
With optical interfaceNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces other1
Supporting protocol for INTERBUSNo
Supporting protocol for TCP/IPYes
Number of HW-interfaces industrial Ethernet0
Supporting protocol for KNXNo
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-2320
Supporting protocol for ASINo
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
With PC connectionYes
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetYes
Mains frequency50/60 Hz
Number of interfaces PROFINET0
4-quadrant operation possibleYes
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes
Relative symmetric net frequency tolerance5%
Integrated breaking resistanceYes
Type of converterU converter
Application in domestic- and commercial area permittedNo
Application in industrial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Max. output at quadratic load at rated output voltage0.75kW
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFINET IOYes
Max. output frequency599Hz
Supporting protocol for Foundation FieldbusNo
Degree of protection (NEMA)4X
Max. output voltage500V
Supporting protocol for BACnetNo
Mains voltage380 - 500V
Nominal output current I2N2.3A
Number of phases input3
Number of phases output3
Max. output at linear load at rated output voltage0.75kW
Supporting protocol for CANYes
Degree of protection (IP)IP66
Supporting protocol for ModbusYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as