Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width250mm
Number of digital inputs7
Number of digital outputs3
Number of HW-interfaces industrial Ethernet0
Number of analogue outputs1
Depth235mm
Height340mm
Supporting protocol for LONNo
With control elementYes
Number of HW-interfaces RS-2320
Number of analogue inputs3
Supporting protocol for PROFIBUSYes
Supporting protocol for ASINo
Number of HW-interfaces serial TTY0
Supporting protocol for CANYes
Number of HW-interfaces USB0
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Number of HW-interfaces parallel0
Supporting protocol for Data-HighwayNo
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Supporting protocol for TCP/IPYes
Supporting protocol for KNXNo
With optical interfaceNo
Number of HW-interfaces other1
Supporting protocol for DeviceNetYes
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
4-quadrant operation possibleYes
Degree of protection (IP)IP65
With PC connectionYes
Mains voltage200 - 240V
Supporting protocol for INTERBUS-SafetyNo
Mains frequency50/60 Hz
Number of interfaces PROFINET0
Integrated breaking resistanceYes
Number of phases input1
Type of converterU converter
Max. output at linear load at rated output voltage1.1kW
Application in domestic- and commercial area permittedNo
Number of phases output3
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET CBANo
Max. output at quadratic load at rated output voltage1.1kW
Max. output frequency599Hz
Relative symmetric net frequency tolerance5%
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IOYes
Application in industrial area permittedYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Nominal output current I2N6.9A
Degree of protection (NEMA)12
Supporting protocol for BACnetNo
Max. output voltage240V
Supporting protocol for PROFIsafeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV320U11M2WS | Frek. Pret. ATV320 1,1KW 200V 1PH Vario

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

250mm

Number of digital inputs

7

Number of digital outputs

3

Number of HW-interfaces industrial Ethernet

0

Number of analogue outputs

1

Depth

235mm

Height

340mm

Supporting protocol for LON

With control element

Number of HW-interfaces RS-232

0

Number of analogue inputs

3

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Number of HW-interfaces serial TTY

0

Supporting protocol for CAN

Number of HW-interfaces USB

0

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Number of HW-interfaces parallel

0

Supporting protocol for Data-Highway

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Supporting protocol for TCP/IP

Supporting protocol for KNX

With optical interface

Number of HW-interfaces other

1

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Supporting protocol for other bus systems

4-quadrant operation possible

Degree of protection (IP)

IP65

With PC connection

Mains voltage

200 .. 240V

Supporting protocol for INTERBUS-Safety

Mains frequency

50/60 Hz

Number of interfaces PROFINET

0

Integrated breaking resistance

Number of phases input

1

Type of converter

U converter

Max. output at linear load at rated output voltage

1.1kW

Application in domestic- and commercial area permitted

Number of phases output

3

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Max. output at quadratic load at rated output voltage

1.1kW

Max. output frequency

599Hz

Relative symmetric net frequency tolerance

5%

Supporting protocol for DeviceNet Safety

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Application in industrial area permitted

Supporting protocol for Foundation Fieldbus

Supporting protocol for SafetyBUS p

Nominal output current I2N

6.9A

Degree of protection (NEMA)

12

Supporting protocol for BACnet

Max. output voltage

240V

Supporting protocol for PROFIsafe

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.