Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Mains voltage380 - 500V
Number of phases output3
Max. output at linear load at rated output voltage1.1kW
Number of digital outputs3
Application in industrial area permittedYes
Supporting protocol for ASINo
Supporting protocol for ModbusYes
Nominal output current I2N3A
Number of digital inputs7
Relative symmetric net frequency tolerance5%
Max. output voltage500V
Max. output at quadratic load at rated output voltage1.1kW
Mains frequency50/60 Hz
Max. output frequency599Hz
Supporting protocol for BACnetNo
Number of analogue inputs3
Number of HW-interfaces industrial Ethernet0
Relative symmetric net voltage tolerance10%
Number of phases input3
Application in domestic- and commercial area permittedNo
With control elementYes
Number of analogue outputs1
Supporting protocol for KNXNo
Supporting protocol for TCP/IPYes
Supporting protocol for INTERBUSNo
Number of HW-interfaces RS-4851
Supporting protocol for DeviceNetYes
Supporting protocol for SUCONETNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for CANYes
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIBUSYes
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Number of interfaces PROFINET0
Number of HW-interfaces USB0
Supporting protocol for LONNo
Supporting protocol for other bus systemsYes
Number of HW-interfaces other1
Number of HW-interfaces RS-4220
Supporting protocol for INTERBUS-SafetyNo
Number of HW-interfaces RS-2320
Supporting protocol for SERCOSNo
Number of HW-interfaces parallel0
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Number of HW-interfaces serial TTY0
With PC connectionYes
Integrated breaking resistanceYes
4-quadrant operation possibleYes
Type of converterU converter
Degree of protection (IP)IP66
With optical interfaceNo
Degree of protection (NEMA)4X
Width250mm
Height340mm
Depth200mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV320U11N4W

Main Product Image

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Mains voltage

380 .. 500V

Number of phases output

3

Max. output at linear load at rated output voltage

1.1kW

Number of digital outputs

3

Application in industrial area permitted

Supporting protocol for ASI

Supporting protocol for Modbus

Nominal output current I2N

3A

Number of digital inputs

7

Relative symmetric net frequency tolerance

5%

Max. output voltage

500V

Max. output at quadratic load at rated output voltage

1.1kW

Mains frequency

50/60 Hz

Max. output frequency

599Hz

Supporting protocol for BACnet

Number of analogue inputs

3

Number of HW-interfaces industrial Ethernet

0

Relative symmetric net voltage tolerance

10%

Number of phases input

3

Application in domestic- and commercial area permitted

With control element

Number of analogue outputs

1

Supporting protocol for KNX

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Number of HW-interfaces RS-485

1

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for EtherNet/IP

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIBUS

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Number of interfaces PROFINET

0

Number of HW-interfaces USB

0

Supporting protocol for LON

Supporting protocol for other bus systems

Number of HW-interfaces other

1

Number of HW-interfaces RS-422

0

Supporting protocol for INTERBUS-Safety

Number of HW-interfaces RS-232

0

Supporting protocol for SERCOS

Number of HW-interfaces parallel

0

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Number of HW-interfaces serial TTY

0

With PC connection

Integrated breaking resistance

4-quadrant operation possible

Type of converter

U converter

Degree of protection (IP)

IP66

With optical interface

Degree of protection (NEMA)

4X

Width

250mm

Height

340mm

Depth

200mm

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.