Number of digital inputs7
Number of digital outputs3
Number of analogue inputs3
Number of analogue outputs1
Number of HW-interfaces parallel0
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Supporting protocol for KNXNo
Number of HW-interfaces RS-4220
Supporting protocol for SUCONETNo
Supporting protocol for CANYes
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4851
Supporting protocol for TCP/IPYes
Supporting protocol for INTERBUSNo
Number of HW-interfaces other1
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFIBUSYes
Supporting protocol for other bus systemsYes
Number of HW-interfaces USB0
Supporting protocol for DeviceNetYes
Supporting protocol for ASINo
Supporting protocol for ModbusYes
Number of HW-interfaces serial TTY0
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET0
4-quadrant operation possibleYes
Type of converterU converter
Supporting protocol for PROFINET IOYes
Application in domestic- and commercial area permittedNo
Max. output frequency599Hz
Max. output at quadratic load at rated output voltage1.5kW
Relative symmetric net voltage tolerance10%
Integrated breaking resistanceYes
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Application in industrial area permittedYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net frequency tolerance5%
Supporting protocol for EtherNet/IPYes
Degree of protection (NEMA)4X
Supporting protocol for BACnetNo
Degree of protection (IP)IP66
Max. output at linear load at rated output voltage1.5kW
Nominal output current I2N4.1A