Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

With control elementYes
Number of digital outputs3
Number of HW-interfaces RS-2320
Supporting protocol for LONNo
Number of analogue outputs1
Number of analogue inputs3
Number of digital inputs7
Height340mm
Number of HW-interfaces RS-4851
Width250mm
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Depth235mm
Supporting protocol for PROFIBUSYes
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
With optical interfaceNo
Number of HW-interfaces other1
Supporting protocol for TCP/IPYes
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
Supporting protocol for CANYes
Supporting protocol for DeviceNetYes
With PC connectionYes
Supporting protocol for INTERBUSNo
Degree of protection (IP)IP66
Integrated breaking resistanceYes
Mains voltage200 - 240V
Application in industrial area permittedYes
Max. output at quadratic load at rated output voltage2.2kW
Supporting protocol for SERCOSNo
Number of phases output3
Type of converterU converter
Application in domestic- and commercial area permittedNo
Max. output frequency599Hz
4-quadrant operation possibleYes
Max. output at linear load at rated output voltage2.2kW
Number of phases input1
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET0
Mains frequency50/60 Hz
Relative symmetric net frequency tolerance5%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFINET IOYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for BACnetNo
Degree of protection (NEMA)4X
Supporting protocol for EtherNet/IPYes
Max. output voltage240V
Nominal output current I2N11A
Supporting protocol for PROFINET CBANo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV320U22M2W

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

With control element

Number of digital outputs

3

Number of HW-interfaces RS-232

0

Supporting protocol for LON

Number of analogue outputs

1

Number of analogue inputs

3

Number of digital inputs

7

Height

340mm

Number of HW-interfaces RS-485

1

Width

250mm

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-422

0

Depth

235mm

Supporting protocol for PROFIBUS

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Number of HW-interfaces parallel

0

With optical interface

Number of HW-interfaces other

1

Supporting protocol for TCP/IP

Supporting protocol for ASI

Supporting protocol for Data-Highway

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Supporting protocol for CAN

Supporting protocol for DeviceNet

With PC connection

Supporting protocol for INTERBUS

Degree of protection (IP)

IP66

Integrated breaking resistance

Mains voltage

200 .. 240V

Application in industrial area permitted

Max. output at quadratic load at rated output voltage

2.2kW

Supporting protocol for SERCOS

Number of phases output

3

Type of converter

U converter

Application in domestic- and commercial area permitted

Max. output frequency

599Hz

4-quadrant operation possible

Max. output at linear load at rated output voltage

2.2kW

Number of phases input

1

Supporting protocol for INTERBUS-Safety

Number of interfaces PROFINET

0

Mains frequency

50/60 Hz

Relative symmetric net frequency tolerance

5%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Supporting protocol for BACnet

Degree of protection (NEMA)

4X

Supporting protocol for EtherNet/IP

Max. output voltage

240V

Nominal output current I2N

11A

Supporting protocol for PROFINET CBA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.