Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of analogue outputs1
Height340mm
Width250mm
Depth235mm
Number of digital outputs3
Number of analogue inputs3
Number of digital inputs7
With control elementYes
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Supporting protocol for LONNo
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces other1
With optical interfaceNo
Number of HW-interfaces serial TTY0
Supporting protocol for CANYes
Supporting protocol for ASINo
Supporting protocol for TCP/IPYes
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSYes
Supporting protocol for ModbusYes
Supporting protocol for KNXNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetYes
Supporting protocol for SUCONETNo
Degree of protection (IP)IP65
Supporting protocol for other bus systemsYes
With PC connectionYes
4-quadrant operation possibleYes
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Number of phases input1
Number of phases output3
Type of converterU converter
Mains voltage200 - 240V
Mains frequency50/60 Hz
Number of interfaces PROFINET0
Integrated breaking resistanceYes
Max. output at quadratic load at rated output voltage2.2kW
Application in domestic- and commercial area permittedNo
Relative symmetric net frequency tolerance5%
Application in industrial area permittedYes
Relative symmetric net voltage tolerance10%
Max. output at linear load at rated output voltage2.2kW
Max. output frequency599Hz
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Max. output voltage240V
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Nominal output current I2N11A
Supporting protocol for BACnetNo
Degree of protection (NEMA)12
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV320U22M2WS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of analogue outputs

1

Height

340mm

Width

250mm

Depth

235mm

Number of digital outputs

3

Number of analogue inputs

3

Number of digital inputs

7

With control element

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-422

0

Supporting protocol for LON

Number of HW-interfaces USB

0

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces other

1

With optical interface

Number of HW-interfaces serial TTY

0

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

Supporting protocol for KNX

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Degree of protection (IP)

IP65

Supporting protocol for other bus systems

With PC connection

4-quadrant operation possible

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Number of phases input

1

Number of phases output

3

Type of converter

U converter

Mains voltage

200 .. 240V

Mains frequency

50/60 Hz

Number of interfaces PROFINET

0

Integrated breaking resistance

Max. output at quadratic load at rated output voltage

2.2kW

Application in domestic- and commercial area permitted

Relative symmetric net frequency tolerance

5%

Application in industrial area permitted

Relative symmetric net voltage tolerance

10%

Max. output at linear load at rated output voltage

2.2kW

Max. output frequency

599Hz

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Max. output voltage

240V

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Nominal output current I2N

11A

Supporting protocol for BACnet

Degree of protection (NEMA)

12

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.