Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth242mm
Width246mm
Height420mm
Number of analogue outputs2
With control elementNo
Number of analogue inputs3
Supporting protocol for LONNo
Number of digital outputs0
Number of HW-interfaces industrial Ethernet0
Number of digital inputs6
Number of HW-interfaces RS-4852
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
Number of HW-interfaces serial TTY0
With optical interfaceNo
Mains frequency50/60 Hz
Supporting protocol for ModbusYes
Number of HW-interfaces USB0
With PC connectionNo
Supporting protocol for PROFIBUSYes
Supporting protocol for TCP/IPYes
Number of HW-interfaces parallel0
Degree of protection (IP)IP21
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetYes
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for other bus systemsNo
Mains voltage500 - 690V
Supporting protocol for KNXNo
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for CANYes
Number of HW-interfaces other0
Integrated breaking resistanceNo
Supporting protocol for EtherNet/IPYes
Number of phases output2
Application in industrial area permittedNo
Supporting protocol for Foundation FieldbusNo
Number of phases input3
Max. output at linear load at rated output voltage18.5kW
Type of converterU converter
Max. output frequency500Hz
Relative symmetric net frequency tolerance5%
Max. output at quadratic load at rated output voltage18.5kW
Relative symmetric net voltage tolerance10%
Supporting protocol for BACnetNo
Max. output voltage690V
Supporting protocol for DeviceNet SafetyNo
Application in domestic- and commercial area permittedNo
Number of interfaces PROFINET0
4-quadrant operation possibleNo
Nominal output current I2N24A
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV630D18Y6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth

242mm

Width

246mm

Height

420mm

Number of analogue outputs

2

With control element

Number of analogue inputs

3

Supporting protocol for LON

Number of digital outputs

0

Number of HW-interfaces industrial Ethernet

0

Number of digital inputs

6

Number of HW-interfaces RS-485

2

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces serial TTY

0

With optical interface

Mains frequency

50/60 Hz

Supporting protocol for Modbus

Number of HW-interfaces USB

0

With PC connection

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Number of HW-interfaces parallel

0

Degree of protection (IP)

IP21

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for other bus systems

Mains voltage

500 .. 690V

Supporting protocol for KNX

Supporting protocol for SUCONET

Supporting protocol for INTERBUS-Safety

Supporting protocol for CAN

Number of HW-interfaces other

0

Integrated breaking resistance

Supporting protocol for EtherNet/IP

Number of phases output

2

Application in industrial area permitted

Supporting protocol for Foundation Fieldbus

Number of phases input

3

Max. output at linear load at rated output voltage

18.5kW

Type of converter

U converter

Max. output frequency

500Hz

Relative symmetric net frequency tolerance

5%

Max. output at quadratic load at rated output voltage

18.5kW

Relative symmetric net voltage tolerance

10%

Supporting protocol for BACnet

Max. output voltage

690V

Supporting protocol for DeviceNet Safety

Application in domestic- and commercial area permitted

Number of interfaces PROFINET

0

4-quadrant operation possible

Nominal output current I2N

24A

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.