Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height630mm
Number of HW-interfaces industrial Ethernet0
Number of analogue inputs3
Number of analogue outputs2
With control elementNo
Width331mm
Number of digital outputs0
Number of digital inputs6
Supporting protocol for LONNo
Depth297mm
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces RS-4220
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4852
Supporting protocol for ASINo
Number of HW-interfaces other0
Number of HW-interfaces RS-2320
With optical interfaceYes
Supporting protocol for PROFIBUSYes
Supporting protocol for TCP/IPYes
Supporting protocol for INTERBUSNo
Supporting protocol for CANYes
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for SERCOSNo
Supporting protocol for other bus systemsNo
Mains frequency50/60 Hz
With PC connectionNo
Supporting protocol for Data-HighwayNo
Mains voltage500 - 690V
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNetYes
Degree of protection (IP)IP00
Number of interfaces PROFINET0
Max. output at quadratic load at rated output voltage75kW
Relative symmetric net voltage tolerance10%
Max. output at linear load at rated output voltage75kW
Relative symmetric net frequency tolerance5%
Integrated breaking resistanceNo
Number of phases output2
Supporting protocol for AS-Interface Safety at WorkNo
Max. output frequency500Hz
Application in industrial area permittedNo
Application in domestic- and commercial area permittedNo
Type of converterU converter
4-quadrant operation possibleNo
Number of phases input3
Supporting protocol for DeviceNet SafetyNo
Max. output voltage690V
Supporting protocol for EtherNet/IPYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
Nominal output current I2N83A
Supporting protocol for BACnetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV630D75Y6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height

630mm

Number of HW-interfaces industrial Ethernet

0

Number of analogue inputs

3

Number of analogue outputs

2

With control element

Width

331mm

Number of digital outputs

0

Number of digital inputs

6

Supporting protocol for LON

Depth

297mm

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-485

2

Supporting protocol for ASI

Number of HW-interfaces other

0

Number of HW-interfaces RS-232

0

With optical interface

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for SERCOS

Supporting protocol for other bus systems

Mains frequency

50/60 Hz

With PC connection

Supporting protocol for Data-Highway

Mains voltage

500 .. 690V

Supporting protocol for SUCONET

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet

Degree of protection (IP)

IP00

Number of interfaces PROFINET

0

Max. output at quadratic load at rated output voltage

75kW

Relative symmetric net voltage tolerance

10%

Max. output at linear load at rated output voltage

75kW

Relative symmetric net frequency tolerance

5%

Integrated breaking resistance

Number of phases output

2

Supporting protocol for AS-Interface Safety at Work

Max. output frequency

500Hz

Application in industrial area permitted

Application in domestic- and commercial area permitted

Type of converter

U converter

4-quadrant operation possible

Number of phases input

3

Supporting protocol for DeviceNet Safety

Max. output voltage

690V

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Nominal output current I2N

83A

Supporting protocol for BACnet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.