Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of HW-interfaces RS-2320
Number of digital inputs6
Supporting protocol for LONNo
Number of HW-interfaces RS-4852
Supporting protocol for TCP/IPYes
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Number of HW-interfaces other0
Number of HW-interfaces parallel0
Depth297mm
Width331mm
With optical interfaceYes
Number of analogue outputs2
Height630mm
With control elementNo
Number of digital outputs0
Number of HW-interfaces USB0
Number of analogue inputs3
Supporting protocol for PROFIBUSYes
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
With PC connectionNo
Supporting protocol for other bus systemsNo
4-quadrant operation possibleNo
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUS-SafetyNo
Mains frequency50/60 Hz
Mains voltage500 - 690V
Type of converterU converter
Number of interfaces PROFINET0
Supporting protocol for SERCOSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetYes
Degree of protection (IP)IP21
Supporting protocol for ModbusYes
Supporting protocol for CANYes
Application in industrial area permittedNo
Number of phases input3
Integrated breaking resistanceNo
Number of phases output2
Max. output at quadratic load at rated output voltage90kW
Max. output frequency500Hz
Application in domestic- and commercial area permittedNo
Max. output at linear load at rated output voltage90kW
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Relative symmetric net frequency tolerance5%
Supporting protocol for EtherNet/IPYes
Supporting protocol for SafetyBUS pNo
Relative symmetric net voltage tolerance10%
Nominal output current I2N108A
Supporting protocol for PROFIsafeNo
Max. output voltage690V
Supporting protocol for BACnetNo
Supporting protocol for Foundation FieldbusNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV630D90Y6 | Frek. Pret. IP00 90KW 500V/690V

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of HW-interfaces RS-232

0

Number of digital inputs

6

Supporting protocol for LON

Number of HW-interfaces RS-485

2

Supporting protocol for TCP/IP

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces other

0

Number of HW-interfaces parallel

0

Depth

297mm

Width

331mm

With optical interface

Number of analogue outputs

2

Height

630mm

With control element

Number of digital outputs

0

Number of HW-interfaces USB

0

Number of analogue inputs

3

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for INTERBUS

Supporting protocol for KNX

With PC connection

Supporting protocol for other bus systems

4-quadrant operation possible

Supporting protocol for SUCONET

Supporting protocol for INTERBUS-Safety

Mains frequency

50/60 Hz

Mains voltage

500 .. 690V

Type of converter

U converter

Number of interfaces PROFINET

0

Supporting protocol for SERCOS

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Degree of protection (IP)

IP21

Supporting protocol for Modbus

Supporting protocol for CAN

Application in industrial area permitted

Number of phases input

3

Integrated breaking resistance

Number of phases output

2

Max. output at quadratic load at rated output voltage

90kW

Max. output frequency

500Hz

Application in domestic- and commercial area permitted

Max. output at linear load at rated output voltage

90kW

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Relative symmetric net frequency tolerance

5%

Supporting protocol for EtherNet/IP

Supporting protocol for SafetyBUS p

Relative symmetric net voltage tolerance

10%

Nominal output current I2N

108A

Supporting protocol for PROFIsafe

Max. output voltage

690V

Supporting protocol for BACnet

Supporting protocol for Foundation Fieldbus

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.