Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth242mm
Height420mm
Width246mm
Number of analogue inputs3
Number of digital outputs1
With control elementYes
Number of HW-interfaces RS-4852
Number of HW-interfaces RS-4220
Number of HW-interfaces USB0
Supporting protocol for CANNo
Supporting protocol for PROFIBUSYes
Supporting protocol for TCP/IPYes
Number of HW-interfaces serial TTY0
Number of HW-interfaces other0
Number of HW-interfaces RS-2320
Supporting protocol for INTERBUSNo
With optical interfaceNo
Supporting protocol for LONNo
Number of HW-interfaces parallel0
Number of HW-interfaces industrial Ethernet2
Supporting protocol for KNXNo
Supporting protocol for ASINo
Number of analogue outputs2
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusYes
Supporting protocol for DeviceNetYes
Number of digital inputs8
Supporting protocol for SERCOSNo
Degree of protection (IP)IP00
With PC connectionNo
Mains voltage500 - 690V
Supporting protocol for other bus systemsNo
Mains frequency50/60 Hz
4-quadrant operation possibleNo
Max. output at linear load at rated output voltage15kW
Supporting protocol for INTERBUS-SafetyNo
Application in industrial area permittedNo
Number of interfaces PROFINET0
Number of phases output2
Number of phases input3
Relative symmetric net frequency tolerance5%
Supporting protocol for DeviceNet SafetyNo
Max. output frequency30000Hz
Supporting protocol for AS-Interface Safety at WorkNo
Type of converterU converter
Relative symmetric net voltage tolerance10%
Application in domestic- and commercial area permittedNo
Integrated breaking resistanceNo
Max. output at quadratic load at rated output voltage15kW
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPYes
Nominal output current I2N18A
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Max. output voltage30V
Supporting protocol for PROFINET IONo
Supporting protocol for BACnetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV930D15Y6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth

242mm

Height

420mm

Width

246mm

Number of analogue inputs

3

Number of digital outputs

1

With control element

Number of HW-interfaces RS-485

2

Number of HW-interfaces RS-422

0

Number of HW-interfaces USB

0

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Number of HW-interfaces serial TTY

0

Number of HW-interfaces other

0

Number of HW-interfaces RS-232

0

Supporting protocol for INTERBUS

With optical interface

Supporting protocol for LON

Number of HW-interfaces parallel

0

Number of HW-interfaces industrial Ethernet

2

Supporting protocol for KNX

Supporting protocol for ASI

Number of analogue outputs

2

Supporting protocol for SUCONET

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Number of digital inputs

8

Supporting protocol for SERCOS

Degree of protection (IP)

IP00

With PC connection

Mains voltage

500 .. 690V

Supporting protocol for other bus systems

Mains frequency

50/60 Hz

4-quadrant operation possible

Max. output at linear load at rated output voltage

15kW

Supporting protocol for INTERBUS-Safety

Application in industrial area permitted

Number of interfaces PROFINET

0

Number of phases output

2

Number of phases input

3

Relative symmetric net frequency tolerance

5%

Supporting protocol for DeviceNet Safety

Max. output frequency

30000Hz

Supporting protocol for AS-Interface Safety at Work

Type of converter

U converter

Relative symmetric net voltage tolerance

10%

Application in domestic- and commercial area permitted

Integrated breaking resistance

Max. output at quadratic load at rated output voltage

15kW

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Nominal output current I2N

18A

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Max. output voltage

30V

Supporting protocol for PROFINET IO

Supporting protocol for BACnet

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.