Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

With control elementYes
Width246mm
Height420mm
Depth242mm
Number of digital inputs8
Number of digital outputs1
With optical interfaceNo
Number of HW-interfaces RS-4220
Number of analogue inputs3
Number of HW-interfaces RS-2320
Supporting protocol for ModbusYes
Supporting protocol for other bus systemsNo
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
Supporting protocol for DeviceNetYes
Supporting protocol for ASINo
Number of HW-interfaces RS-4852
Supporting protocol for SUCONETNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSYes
Degree of protection (IP)IP00
Number of HW-interfaces industrial Ethernet2
Supporting protocol for KNXNo
Number of HW-interfaces parallel0
Supporting protocol for TCP/IPYes
Supporting protocol for Data-HighwayNo
Number of analogue outputs2
Supporting protocol for LONNo
Number of HW-interfaces other0
Supporting protocol for PROFINET IONo
Supporting protocol for DeviceNet SafetyNo
Number of phases output2
Integrated breaking resistanceNo
Max. output frequency30000Hz
4-quadrant operation possibleNo
Number of interfaces PROFINET0
Application in industrial area permittedNo
Supporting protocol for PROFINET CBANo
Max. output at quadratic load at rated output voltage2.2kW
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for Foundation FieldbusNo
Mains frequency50/60 Hz
Relative symmetric net voltage tolerance10%
With PC connectionNo
Type of converterU converter
Max. output at linear load at rated output voltage2.2kW
Application in domestic- and commercial area permittedNo
Mains voltage500 - 690V
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPYes
Number of phases input3
Relative symmetric net frequency tolerance5%
Supporting protocol for SERCOSNo
Supporting protocol for PROFIsafeNo
Supporting protocol for BACnetNo
Nominal output current I2N3.1A
Supporting protocol for SafetyBUS pNo
Max. output voltage30V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ATV930U22Y6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

With control element

Width

246mm

Height

420mm

Depth

242mm

Number of digital inputs

8

Number of digital outputs

1

With optical interface

Number of HW-interfaces RS-422

0

Number of analogue inputs

3

Number of HW-interfaces RS-232

0

Supporting protocol for Modbus

Supporting protocol for other bus systems

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

Supporting protocol for DeviceNet

Supporting protocol for ASI

Number of HW-interfaces RS-485

2

Supporting protocol for SUCONET

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Degree of protection (IP)

IP00

Number of HW-interfaces industrial Ethernet

2

Supporting protocol for KNX

Number of HW-interfaces parallel

0

Supporting protocol for TCP/IP

Supporting protocol for Data-Highway

Number of analogue outputs

2

Supporting protocol for LON

Number of HW-interfaces other

0

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet Safety

Number of phases output

2

Integrated breaking resistance

Max. output frequency

30000Hz

4-quadrant operation possible

Number of interfaces PROFINET

0

Application in industrial area permitted

Supporting protocol for PROFINET CBA

Max. output at quadratic load at rated output voltage

2.2kW

Supporting protocol for INTERBUS-Safety

Supporting protocol for Foundation Fieldbus

Mains frequency

50/60 Hz

Relative symmetric net voltage tolerance

10%

With PC connection

Type of converter

U converter

Max. output at linear load at rated output voltage

2.2kW

Application in domestic- and commercial area permitted

Mains voltage

500 .. 690V

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Number of phases input

3

Relative symmetric net frequency tolerance

5%

Supporting protocol for SERCOS

Supporting protocol for PROFIsafe

Supporting protocol for BACnet

Nominal output current I2N

3.1A

Supporting protocol for SafetyBUS p

Max. output voltage

30V

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.