Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)IP40
Type of control elementToggle
Number of poles4
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu100A
Motor drive optionalNo
Overload release current setting70 - 100A
Motor drive integratedNo
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as change-over contact0
Device constructionBuilt-in device fixed built-in technique
Rated voltage690 - 690V
Adjustment range undelayed short-circuit release1250 - 1250A
Suitable for DIN rail (top hat rail) mountingYes
With switched-off indicatorYes
Adjustment range short-term delayed short-circuit release- - -A
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalNo
With under voltage releaseNo
Complete device with protection unitYes
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV426527

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP40

Type of control element

Toggle

Number of poles

4

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

100A

Motor drive optional

Overload release current setting

70 .. 100A

Motor drive integrated

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as change-over contact

0

Device construction

Built-in device fixed built-in technique

Rated voltage

690 .. 690V

Adjustment range undelayed short-circuit release

1250 .. 1250A

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Adjustment range short-term delayed short-circuit release

- .. -A

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

With under voltage release

Complete device with protection unit

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA