Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • ABB

Technical specifications

Number of command positions16
Depth114.5mm
Height99mm
With transformerNo
Rated operation power at AC-3, 400 V0.18kW
Width22.5mm
Number of auxiliary contacts as normally closed contact-
Rated operation current Ie0.6A
Number of auxiliary contacts as normally open contact-
Suitable for emergency stopNo
Number of indicator lights4
Overload release current setting0.075 - 0.600A
Supporting protocol for CANNo
Supporting protocol for LONNo
Supporting protocol for TCP/IPNo
Supporting protocol for other bus systemsNo
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusNo
Supporting protocol for SUCONETNo
External reset possibleYes
Supporting protocol for PROFIBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
With short-circuit releaseNo
Rail mounting possibleYes
Rated control supply voltage Us at AC 60HZ0 - 0V
Release classCLASS 10 A
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 24V
Type of electrical connection of main circuitScrew connection
Supporting protocol for SERCOSNo
Rated control supply voltage Us at AC 50HZ0 - 0V
With fuseNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Ambient temperature, upper operating limit80°C
Supporting protocol for EtherNet/IPNo
Rated power, 575 V, 60 Hz, 3-phase-kW
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IONo
Rated conditional short-circuit current, type 2, 400 V-A
Voltage type for actuatingDC
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V0.6A
Rated power, 460 V, 60 Hz, 3-phase-kW
Supporting protocol for AS-Interface Safety at WorkNo
Rated operation power at AC-3, 230 V, 3-phase0.09kW
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 230 V-A
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Degree of protection (NEMA)1
Type of electrical connection for auxiliary- and control current circuitScrew connection
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SAT112000R1011 | HF0.6-DOL ELECTRONIC COMPACT STARTER 24V

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • ABB

Technical specifications

Number of command positions

16

Depth

114.5mm

Height

99mm

With transformer

Rated operation power at AC-3, 400 V

0.18kW

Width

22.5mm

Number of auxiliary contacts as normally closed contact

-

Rated operation current Ie

0.6A

Number of auxiliary contacts as normally open contact

-

Suitable for emergency stop

Number of indicator lights

4

Overload release current setting

0.075 .. 0.600A

Supporting protocol for CAN

Supporting protocol for LON

Supporting protocol for TCP/IP

Supporting protocol for other bus systems

Supporting protocol for ASI

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for SUCONET

External reset possible

Supporting protocol for PROFIBUS

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

With short-circuit release

Rail mounting possible

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Release class

CLASS 10 A

Degree of protection (IP)

IP20

Rated control supply voltage Us at DC

24 .. 24V

Type of electrical connection of main circuit

Screw connection

Supporting protocol for SERCOS

Rated control supply voltage Us at AC 50HZ

0 .. 0V

With fuse

Supporting protocol for INTERBUS-Safety

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Ambient temperature, upper operating limit

80°C

Supporting protocol for EtherNet/IP

Rated power, 575 V, 60 Hz, 3-phase

-kW

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Rated conditional short-circuit current, type 2, 400 V

-A

Voltage type for actuating

DC

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Type of motor starter

Direct online starter (DOL)

Rated operation current at AC-3, 400 V

0.6A

Rated power, 460 V, 60 Hz, 3-phase

-kW

Supporting protocol for AS-Interface Safety at Work

Rated operation power at AC-3, 230 V, 3-phase

0.09kW

Temperature compensated overload protection

Rated conditional short-circuit current, type 2, 230 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Degree of protection (NEMA)

1

Type of electrical connection for auxiliary- and control current circuit

Screw connection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.