Technical specifications
1SAT115000R1011 | HF0.6-ROL ELECTRONIC COMPACT STARTER 24V

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- ABB
Technical specifications
Depth
114.5mm
With transformer
Rated operation power at AC-3, 400 V
0.18kW
Width
22.5mm
Height
99mm
Number of auxiliary contacts as normally open contact
-
Number of command positions
16
Number of auxiliary contacts as normally closed contact
-
Supporting protocol for INTERBUS
Number of indicator lights
4
Rated operation current Ie
0.6A
External reset possible
Supporting protocol for SUCONET
Release class
CLASS 10 A
Suitable for emergency stop
Supporting protocol for Modbus
Rail mounting possible
Supporting protocol for CAN
Supporting protocol for PROFIBUS
Supporting protocol for other bus systems
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Supporting protocol for TCP/IP
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for INTERBUS-Safety
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Supporting protocol for SERCOS
Supporting protocol for DeviceNet
Supporting protocol for ASI
Supporting protocol for Data-Highway
Degree of protection (IP)
IP20
With short-circuit release
Overload release current setting
0.075 .. 0.600A
Supporting protocol for LON
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for PROFINET CBA
Type of electrical connection of main circuit
Screw connection
With fuse
Rated conditional short-circuit current, type 2, 400 V
-A
Supporting protocol for EtherNet/IP
Degree of protection (NEMA)
1
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated power, 460 V, 60 Hz, 3-phase
-kW
Supporting protocol for PROFIsafe
Ambient temperature, upper operating limit
80°C
Voltage type for actuating
DC
Rated conditional short-circuit current, type 2, 230 V
-A
Supporting protocol for SafetyBUS p
Supporting protocol for Foundation Fieldbus
Rated operation power at AC-3, 230 V, 3-phase
0.09kW
Temperature compensated overload protection
Rated operation current at AC-3, 400 V
0.6A
Type of motor starter
Reversing starter
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET IO
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A