Technical specifications

Number of command positions16
With transformerNo
Height99mm
Width22.5mm
Depth114.5mm
Number of auxiliary contacts as normally open contact-
Number of auxiliary contacts as normally closed contact-
Suitable for emergency stopNo
Supporting protocol for other bus systemsNo
Supporting protocol for CANNo
Supporting protocol for ModbusNo
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Supporting protocol for DeviceNetNo
Supporting protocol for LONNo
Number of indicator lights4
Supporting protocol for ASINo
Rail mounting possibleYes
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
External reset possibleYes
Supporting protocol for SUCONETNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
With short-circuit releaseNo
Release classCLASS 10 A
Supporting protocol for AS-Interface Safety at WorkNo
With fuseNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for SafetyBUS pNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for DeviceNet SafetyNo
Rated operation power at AC-3, 230 V, 3-phase0.37kW
Supporting protocol for PROFINET IONo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Rated conditional short-circuit current, type 2, 400 V-A
Voltage type for actuatingDC
Degree of protection (NEMA)1
Supporting protocol for Foundation FieldbusNo
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 230 V-A
Supporting protocol for PROFINET CBANo
Ambient temperature, upper operating limit80°C
Rated power, 575 V, 60 Hz, 3-phase-kW
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Supporting protocol for PROFIsafeNo
Rated power, 460 V, 60 Hz, 3-phase-kW
Rated operation power at AC-3, 400 V0.75kW
Rated operation current Ie2.4A
Overload release current setting0.18 - 2.4A
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 24V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V2.4A