Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact-
Number of auxiliary contacts as normally closed contact-
Depth114.5mm
Number of command positions16
Rated operation power at AC-3, 400 V0.75kW
Number of indicator lights4
Suitable for emergency stopNo
With transformerNo
Rated operation current Ie2.4A
Width22.5mm
Height99mm
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusNo
Supporting protocol for DeviceNetNo
Overload release current setting0.18 - 2.4A
Supporting protocol for LONNo
Supporting protocol for ASINo
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
External reset possibleYes
Rated control supply voltage Us at AC 50HZ0 - 0V
Rail mounting possibleYes
Degree of protection (IP)IP20
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for AS-Interface Safety at WorkNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for DeviceNet SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
With fuseNo
Release classCLASS 10 A
With short-circuit releaseNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Type of motor starterReversing starter
Rated power, 575 V, 60 Hz, 3-phase-kW
Rated power, 460 V, 60 Hz, 3-phase-kW
Voltage type for actuatingDC
Rated operation power at AC-3, 230 V, 3-phase0.37kW
Rated control supply voltage Us at DC24 - 24V
Rated operation current at AC-3, 400 V2.4A
Ambient temperature, upper operating limit80°C
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Rated conditional short-circuit current, type 2, 230 V-A
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Degree of protection (NEMA)1
Rated conditional short-circuit current, type 2, 400 V-A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SAT125000R1011 | HF2.4-ROL ELECTRONIC COMPACT STARTER 24V

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

-

Number of auxiliary contacts as normally closed contact

-

Depth

114.5mm

Number of command positions

16

Rated operation power at AC-3, 400 V

0.75kW

Number of indicator lights

4

Suitable for emergency stop

With transformer

Rated operation current Ie

2.4A

Width

22.5mm

Height

99mm

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Overload release current setting

0.18 .. 2.4A

Supporting protocol for LON

Supporting protocol for ASI

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for SUCONET

Supporting protocol for other bus systems

External reset possible

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rail mounting possible

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for AS-Interface Safety at Work

Type of electrical connection of main circuit

Screw connection

Supporting protocol for DeviceNet Safety

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With fuse

Release class

CLASS 10 A

With short-circuit release

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Type of motor starter

Reversing starter

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated power, 460 V, 60 Hz, 3-phase

-kW

Voltage type for actuating

DC

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Rated control supply voltage Us at DC

24 .. 24V

Rated operation current at AC-3, 400 V

2.4A

Ambient temperature, upper operating limit

80°C

Temperature compensated overload protection

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Degree of protection (NEMA)

1

Rated conditional short-circuit current, type 2, 400 V

-A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.