Technical specifications

Width22.5mm
With transformerNo
Height99mm
Depth114.5mm
Number of auxiliary contacts as normally closed contact-
Number of command positions16
Suitable for emergency stopNo
Number of auxiliary contacts as normally open contact-
Supporting protocol for INTERBUSNo
Supporting protocol for TCP/IPNo
Number of indicator lights4
Supporting protocol for CANNo
Supporting protocol for LONNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at AC 50HZ0 - 0V
Rail mounting possibleYes
Supporting protocol for other bus systemsNo
External reset possibleYes
Supporting protocol for SUCONETNo
Supporting protocol for ModbusNo
Supporting protocol for DeviceNetNo
Release classCLASS 10 A
With short-circuit releaseNo
Supporting protocol for Data-HighwayNo
With fuseNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFIsafeNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for INTERBUS-SafetyNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Voltage type for actuatingDC
Rated conditional short-circuit current, type 2, 230 V-A
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated conditional short-circuit current, type 2, 400 V-A
Supporting protocol for SafetyBUS pNo
Rated power, 460 V, 60 Hz, 3-phase-kW
Rated power, 575 V, 60 Hz, 3-phase-kW
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Rated operation power at AC-3, 230 V, 3-phase0.37kW
Ambient temperature, upper operating limit80°C
Degree of protection (NEMA)1
Temperature compensated overload protectionYes
Rated operation power at AC-3, 400 V0.75kW
Rated operation current Ie2.4A
Overload release current setting0.18 - 2.4A
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 24V
Type of motor starterReversing starter
Rated operation current at AC-3, 400 V2.4A