Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • ABB

Technical specifications

Height99mm
Suitable for emergency stopNo
Number of auxiliary contacts as normally open contact-
Width22.5mm
With transformerNo
Number of command positions16
Number of auxiliary contacts as normally closed contact-
Depth114.5mm
Rated operation power at AC-3, 400 V3kW
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusNo
Supporting protocol for TCP/IPNo
Number of indicator lights4
Overload release current setting1.5 - 9.0A
Supporting protocol for DeviceNetNo
Supporting protocol for CANNo
Rated operation current Ie9A
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for LONNo
Supporting protocol for ASINo
Degree of protection (IP)IP20
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Rated control supply voltage Us at DC24 - 24V
External reset possibleYes
Supporting protocol for other bus systemsNo
Release classCLASS 10 A
Rated control supply voltage Us at AC 50HZ0 - 0V
Supporting protocol for INTERBUS-SafetyNo
Rail mounting possibleYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IONo
With short-circuit releaseNo
Supporting protocol for SafetyBUS pNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Type of motor starterDirect online starter (DOL)
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFIsafeNo
Supporting protocol for AS-Interface Safety at WorkNo
Type of electrical connection of main circuitScrew connection
Voltage type for actuatingDC
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
With fuseNo
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Degree of protection (NEMA)1
Rated power, 460 V, 60 Hz, 3-phase-kW
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Rated power, 575 V, 60 Hz, 3-phase-kW
Ambient temperature, upper operating limit80°C
Rated conditional short-circuit current, type 2, 230 V-A
Rated operation power at AC-3, 230 V, 3-phase1.50kW
Rated conditional short-circuit current, type 2, 400 V-A
Rated operation current at AC-3, 400 V6.5A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SAT142000R1011 | HF9-DOL ELECTRONIC COMPACT STARTER 24VDC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • ABB

Technical specifications

Height

99mm

Suitable for emergency stop

Number of auxiliary contacts as normally open contact

-

Width

22.5mm

With transformer

Number of command positions

16

Number of auxiliary contacts as normally closed contact

-

Depth

114.5mm

Rated operation power at AC-3, 400 V

3kW

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

Supporting protocol for TCP/IP

Number of indicator lights

4

Overload release current setting

1.5 .. 9.0A

Supporting protocol for DeviceNet

Supporting protocol for CAN

Rated operation current Ie

9A

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for LON

Supporting protocol for ASI

Degree of protection (IP)

IP20

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Rated control supply voltage Us at DC

24 .. 24V

External reset possible

Supporting protocol for other bus systems

Release class

CLASS 10 A

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Supporting protocol for INTERBUS-Safety

Rail mounting possible

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

With short-circuit release

Supporting protocol for SafetyBUS p

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Type of motor starter

Direct online starter (DOL)

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIsafe

Supporting protocol for AS-Interface Safety at Work

Type of electrical connection of main circuit

Screw connection

Voltage type for actuating

DC

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

With fuse

Temperature compensated overload protection

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Degree of protection (NEMA)

1

Rated power, 460 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Ambient temperature, upper operating limit

80°C

Rated conditional short-circuit current, type 2, 230 V

-A

Rated operation power at AC-3, 230 V, 3-phase

1.50kW

Rated conditional short-circuit current, type 2, 400 V

-A

Rated operation current at AC-3, 400 V

6.5A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.