Details
- •Low-voltage industrial components
- •Motor starter/Motor starter combination
- •1 KOM
- •ABB
Technical specifications
1SAT143000R1011 | HF9-DOLE ELECTRONIC COMPACT STARTER 24VD

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- ABB
Technical specifications
With transformer
Width
22.5mm
Number of indicator lights
4
Depth
114.5mm
Number of command positions
16
Number of auxiliary contacts as normally closed contact
-
Height
99mm
Number of auxiliary contacts as normally open contact
-
Suitable for emergency stop
Supporting protocol for INTERBUS
Supporting protocol for Data-Highway
Supporting protocol for ASI
Supporting protocol for CAN
Supporting protocol for Modbus
Supporting protocol for TCP/IP
Supporting protocol for DeviceNet
Supporting protocol for PROFIBUS
Supporting protocol for LON
Supporting protocol for other bus systems
Supporting protocol for INTERBUS-Safety
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for PROFIsafe
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Supporting protocol for SUCONET
Release class
CLASS 10 A
Supporting protocol for SERCOS
Supporting protocol for SafetyBUS p
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
External reset possible
Rated control supply voltage Us at AC 50HZ
0 .. 0V
With fuse
Supporting protocol for DeviceNet Safety
Rail mounting possible
Supporting protocol for EtherNet/IP
With short-circuit release
Voltage type for actuating
DC
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Ambient temperature, upper operating limit
80°C
Degree of protection (NEMA)
1
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated operation power at AC-3, 230 V, 3-phase
1.50kW
Rated conditional short-circuit current, type 2, 400 V
-A
Rated power, 460 V, 60 Hz, 3-phase
-kW
Temperature compensated overload protection
Rated operation power at AC-3, 400 V
3kW
Rated operation current Ie
9A
Overload release current setting
1.5 .. 9.0A
Degree of protection (IP)
IP20
Rated control supply voltage Us at DC
24 .. 24V
Type of motor starter
Direct online starter (DOL)
Rated operation current at AC-3, 400 V
6.5A