Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • ABB

Technical specifications

Rated operation power at AC-3, 400 V3kW
Number of auxiliary contacts as normally open contact-
Suitable for emergency stopNo
Number of command positions16
Depth114.5mm
Number of auxiliary contacts as normally closed contact-
Width22.5mm
Height99mm
Number of indicator lights4
Supporting protocol for ModbusNo
Supporting protocol for CANNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Supporting protocol for TCP/IPNo
Rated operation current Ie9A
Supporting protocol for Data-HighwayNo
With transformerNo
Overload release current setting1.5 - 9.0A
Supporting protocol for LONNo
Supporting protocol for other bus systemsNo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Rated control supply voltage Us at DC24 - 24V
Degree of protection (IP)IP20
Rated control supply voltage Us at AC 60HZ0 - 0V
External reset possibleYes
Rated control supply voltage Us at AC 50HZ0 - 0V
Rail mounting possibleYes
Type of electrical connection of main circuitScrew connection
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET CBANo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
With fuseNo
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPNo
Release classCLASS 10 A
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for Foundation FieldbusNo
Voltage type for actuatingDC
With short-circuit releaseNo
Supporting protocol for SafetyBUS pNo
Rated operation power at AC-3, 230 V, 3-phase1.50kW
Rated conditional short-circuit current, type 2, 230 V-A
Type of motor starterReversing starter
Ambient temperature, upper operating limit80°C
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Degree of protection (NEMA)1
Rated power, 460 V, 60 Hz, 3-phase-kW
Rated conditional short-circuit current, type 2, 400 V-A
Rated power, 575 V, 60 Hz, 3-phase-kW
Rated operation current at AC-3, 400 V6.5A
Temperature compensated overload protectionYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SAT145000R1011 | HF9-ROL ELECTRONIC COMPACT STARTER 24VDC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • ABB

Technical specifications

Rated operation power at AC-3, 400 V

3kW

Number of auxiliary contacts as normally open contact

-

Suitable for emergency stop

Number of command positions

16

Depth

114.5mm

Number of auxiliary contacts as normally closed contact

-

Width

22.5mm

Height

99mm

Number of indicator lights

4

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for TCP/IP

Rated operation current Ie

9A

Supporting protocol for Data-Highway

With transformer

Overload release current setting

1.5 .. 9.0A

Supporting protocol for LON

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Rated control supply voltage Us at DC

24 .. 24V

Degree of protection (IP)

IP20

Rated control supply voltage Us at AC 60HZ

0 .. 0V

External reset possible

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rail mounting possible

Type of electrical connection of main circuit

Screw connection

Supporting protocol for SERCOS

Supporting protocol for PROFINET CBA

Supporting protocol for INTERBUS-Safety

Supporting protocol for AS-Interface Safety at Work

With fuse

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Release class

CLASS 10 A

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for Foundation Fieldbus

Voltage type for actuating

DC

With short-circuit release

Supporting protocol for SafetyBUS p

Rated operation power at AC-3, 230 V, 3-phase

1.50kW

Rated conditional short-circuit current, type 2, 230 V

-A

Type of motor starter

Reversing starter

Ambient temperature, upper operating limit

80°C

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Degree of protection (NEMA)

1

Rated power, 460 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 2, 400 V

-A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated operation current at AC-3, 400 V

6.5A

Temperature compensated overload protection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.