  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • ABB

Technical specifications

Depth114.5mm
With transformerNo
Height99mm
Number of command positions16
Width22.5mm
Rated operation current Ie9A
Rated operation power at AC-3, 400 V3kW
Suitable for emergency stopNo
Number of auxiliary contacts as normally open contact-
Number of auxiliary contacts as normally closed contact-
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusNo
Supporting protocol for LONNo
Rated control supply voltage Us at DC24 - 24V
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Overload release current setting1.5 - 9.0A
Supporting protocol for other bus systemsNo
Supporting protocol for SUCONETNo
Supporting protocol for ASINo
External reset possibleYes
Rail mounting possibleYes
Supporting protocol for Data-HighwayNo
Supporting protocol for CANNo
Number of indicator lights4
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for DeviceNetNo
Rated control supply voltage Us at AC 50HZ0 - 0V
With fuseNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for SERCOSNo
With short-circuit releaseNo
Degree of protection (IP)IP20
Supporting protocol for INTERBUS-SafetyNo
Release classCLASS 10 A
Rated power, 575 V, 60 Hz, 3-phase-kW
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Type of motor starterReversing starter
Supporting protocol for SafetyBUS pNo
Rated power, 460 V, 60 Hz, 3-phase-kW
Supporting protocol for PROFINET CBANo
Rated operation current at AC-3, 400 V6.5A
Rated conditional short-circuit current, type 2, 400 V-A
Voltage type for actuatingDC
Rated operation power at AC-3, 230 V, 3-phase1.50kW
Supporting protocol for EtherNet/IPNo
Rated conditional short-circuit current, type 2, 230 V-A
Temperature compensated overload protectionYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Ambient temperature, upper operating limit80°C
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Degree of protection (NEMA)1
Supporting protocol for PROFIsafeNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SAT146000R1011 | HF9-ROLE ELECTRONIC COMPACT STARTER 24VD

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • ABB

Technical specifications

Depth

114.5mm

With transformer

Height

99mm

Number of command positions

16

Width

22.5mm

Rated operation current Ie

9A

Rated operation power at AC-3, 400 V

3kW

Suitable for emergency stop

Number of auxiliary contacts as normally open contact

-

Number of auxiliary contacts as normally closed contact

-

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for LON

Rated control supply voltage Us at DC

24 .. 24V

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Overload release current setting

1.5 .. 9.0A

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Supporting protocol for ASI

External reset possible

Rail mounting possible

Supporting protocol for Data-Highway

Supporting protocol for CAN

Number of indicator lights

4

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Supporting protocol for DeviceNet

Rated control supply voltage Us at AC 50HZ

0 .. 0V

With fuse

Type of electrical connection of main circuit

Screw connection

Supporting protocol for SERCOS

With short-circuit release

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS-Safety

Release class

CLASS 10 A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for AS-Interface Safety at Work

Type of motor starter

Reversing starter

Supporting protocol for SafetyBUS p

Rated power, 460 V, 60 Hz, 3-phase

-kW

Supporting protocol for PROFINET CBA

Rated operation current at AC-3, 400 V

6.5A

Rated conditional short-circuit current, type 2, 400 V

-A

Voltage type for actuating

DC

Rated operation power at AC-3, 230 V, 3-phase

1.50kW

Supporting protocol for EtherNet/IP

Rated conditional short-circuit current, type 2, 230 V

-A

Temperature compensated overload protection

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Supporting protocol for Foundation Fieldbus

Ambient temperature, upper operating limit

80°C

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Degree of protection (NEMA)

1

Supporting protocol for PROFIsafe

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.