Technical specifications
Depth
114.5mm
With transformer
Height
99mm
Number of command positions
16
Width
22.5mm
Rated operation current Ie
9A
Rated operation power at AC-3, 400 V
3kW
Suitable for emergency stop
Number of auxiliary contacts as normally open contact
-
Number of auxiliary contacts as normally closed contact
-
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for LON
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for PROFIBUS
Supporting protocol for TCP/IP
Overload release current setting
1.5 .. 9.0A
Supporting protocol for other bus systems
Supporting protocol for SUCONET
Supporting protocol for ASI
External reset possible
Rail mounting possible
Supporting protocol for Data-Highway
Supporting protocol for CAN
Number of indicator lights
4
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Supporting protocol for DeviceNet
Rated control supply voltage Us at AC 50HZ
0 .. 0V
With fuse
Type of electrical connection of main circuit
Screw connection
Supporting protocol for SERCOS
With short-circuit release
Degree of protection (IP)
IP20
Supporting protocol for INTERBUS-Safety
Release class
CLASS 10 A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for AS-Interface Safety at Work
Type of motor starter
Reversing starter
Supporting protocol for SafetyBUS p
Rated power, 460 V, 60 Hz, 3-phase
-kW
Supporting protocol for PROFINET CBA
Rated operation current at AC-3, 400 V
6.5A
Rated conditional short-circuit current, type 2, 400 V
-A
Voltage type for actuating
DC
Rated operation power at AC-3, 230 V, 3-phase
1.50kW
Supporting protocol for EtherNet/IP
Rated conditional short-circuit current, type 2, 230 V
-A
Temperature compensated overload protection
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
Ambient temperature, upper operating limit
80°C
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Degree of protection (NEMA)
1
Supporting protocol for PROFIsafe