Aleta.hr
Announcement

Registration is currently available to business customers only (B2B).

Details

  • •Low-voltage industrial components
  • •Motor starter/Motor starter combination
  • •Minimum order quantity: 1 pcs
  • •ABB

Technical specifications

Depth114.5mm
With transformerNo
Height99mm
Number of command positions16
Width22.5mm
Suitable for emergency stopNo
Number of auxiliary contacts as normally open contact-
Number of auxiliary contacts as normally closed contact-
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusNo
Supporting protocol for LONNo
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Supporting protocol for other bus systemsNo
Supporting protocol for SUCONETNo
Supporting protocol for ASINo
External reset possibleYes
Rail mounting possibleYes
Supporting protocol for Data-HighwayNo
Supporting protocol for CANNo
Number of indicator lights4
Rated control supply voltage Us at AC 60HZ0 - 0V
Supporting protocol for DeviceNetNo
Rated control supply voltage Us at AC 50HZ0 - 0V
With fuseNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for SERCOSNo
With short-circuit releaseNo
Supporting protocol for INTERBUS-SafetyNo
Release classCLASS 10 A
Rated power, 575 V, 60 Hz, 3-phase-kW
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for SafetyBUS pNo
Rated power, 460 V, 60 Hz, 3-phase-kW
Supporting protocol for PROFINET CBANo
Rated conditional short-circuit current, type 2, 400 V-A
Voltage type for actuatingDC
Rated operation power at AC-3, 230 V, 3-phase1.5kW
Supporting protocol for EtherNet/IPNo
Rated conditional short-circuit current, type 2, 230 V-A
Temperature compensated overload protectionYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Ambient temperature, upper operating limit80°C
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Degree of protection (NEMA)1
Supporting protocol for PROFIsafeNo
Rated operation power at AC-3, 400 V3kW
Rated operation current Ie9A
Overload release current setting1.5 - 9A
Degree of protection (IP)IP20
Rated control supply voltage Us at DC24 - 24V
Type of motor starterReversing starter
Rated operation current at AC-3, 400 V6.5A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as