Technical specifications

Voltage typeDC
Built-in depth111mm
Frequency0 - 0Hz
Rated current16A
Release characteristicB
Rated voltage1500V
Current limiting class3
Over voltage category3
Number of protected poles2
Width in number of modular spacings2
Rated insulation voltage Ui1500V
Pollution degree2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V5kA
Concurrently switching neutral conductorNo
Additional equipment possibleNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V5kA
Degree of protection (IP)IP20
Number of poles (total)2
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 70mm²
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V5kA
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V5kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019599R0001 | S802PV-SP16 HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

DC

Built-in depth

111mm

Frequency

0 .. 0Hz

Rated current

16A

Release characteristic

B

Rated voltage

1500V

Current limiting class

3

Over voltage category

3

Number of protected poles

2

Width in number of modular spacings

2

Rated insulation voltage Ui

1500V

Pollution degree

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

5kA

Concurrently switching neutral conductor

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

5kA

Degree of protection (IP)

IP20

Number of poles (total)

2

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 70mm²

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

5kA

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

5kA

Rated impulse withstand voltage Uimp

8kV