2CCF019602R0001 | S802PV-SP32 HIGH PERFORMANCE MCB

Code: 1857339

ManufacturerABB
Catalog number2CCF019602R0001
EAN code7612271471293

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth111mm
Rated voltage1500V
Voltage typeDC
Frequency0 - 0Hz
Rated current32A
Current limiting class3
Over voltage category3
Additional equipment possibleNo
Pollution degree2
Connectable conductor cross section multi-wired0 - 70mm²
Release characteristicB
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V5kA
Concurrently switching neutral conductorNo
Rated insulation voltage Ui1500V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V5kA
Width in number of modular spacings2
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V5kA
Ambient temperature during operating-25 - 60°C
Number of protected poles2
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V5kA
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019602R0001 | S802PV-SP32 HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

111mm

Rated voltage

1500V

Voltage type

DC

Frequency

0 .. 0Hz

Rated current

32A

Current limiting class

3

Over voltage category

3

Additional equipment possible

Pollution degree

2

Connectable conductor cross section multi-wired

0 .. 70mm²

Release characteristic

B

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

5kA

Concurrently switching neutral conductor

Rated insulation voltage Ui

1500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

5kA

Width in number of modular spacings

2

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

5kA

Ambient temperature during operating

-25 .. 60°C

Number of protected poles

2

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

5kA

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

8kV