Aleta.hr
Main Product Image

2CCF019603R0001 | S802PV-SP40 HIGH PERFORMANCE MCB

Code: 1857340

ManufacturerABB
Catalog number2CCF019603R0001
EAN code7612271471316

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicB
Rated current40A
Number of poles (total)2
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V5kA
Rated insulation voltage Ui1500V
Rated impulse withstand voltage Uimp8kV
Rated voltage1500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V5kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V5kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V5kA
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Additional equipment possibleNo
Voltage typeDC
Pollution degree2
Over voltage category3
Current limiting class3
Built-in depth111mm
Width in number of modular spacings2
Degree of protection (IP)IP20
Frequency0 - 0Hz
Connectable conductor cross section multi-wired0 - 70mm²
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019603R0001 | S802PV-SP40 HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Rated current

40A

Number of poles (total)

2

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

5kA

Rated insulation voltage Ui

1500V

Rated impulse withstand voltage Uimp

8kV

Rated voltage

1500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

5kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

5kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

5kA

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Additional equipment possible

Voltage type

DC

Pollution degree

2

Over voltage category

3

Current limiting class

3

Built-in depth

111mm

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Frequency

0 .. 0Hz

Connectable conductor cross section multi-wired

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 50mm²