Aleta.hr
Main Product Image

2CCF019606R0001 | S802PV-SP80 HIGH PERFORMANCE MCB

Code: 1857343

ManufacturerABB
Catalog number2CCF019606R0001
EAN code7612271471378

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicB
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V5kA
Rated insulation voltage Ui1500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V5kA
Over voltage category3
Frequency0 - 0Hz
Rated voltage1500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V5kA
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorNo
Voltage typeDC
Degree of protection (IP)IP20
Width in number of modular spacings2
Rated current80A
Number of protected poles2
Additional equipment possibleNo
Rated impulse withstand voltage Uimp8kV
Built-in depth111mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V5kA
Current limiting class3
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 50mm²
Pollution degree2
Connectable conductor cross section multi-wired0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCF019606R0001 | S802PV-SP80 HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

5kA

Rated insulation voltage Ui

1500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

5kA

Over voltage category

3

Frequency

0 .. 0Hz

Rated voltage

1500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

5kA

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Voltage type

DC

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Rated current

80A

Number of protected poles

2

Additional equipment possible

Rated impulse withstand voltage Uimp

8kV

Built-in depth

111mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

5kA

Current limiting class

3

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 50mm²

Pollution degree

2

Connectable conductor cross section multi-wired

0 .. 70mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.