Aleta.hr
Main Product Image

2CCF019629R0001 | S804PV-SP50 HIGH PERFORMANCE MCB

Code: 1857366

ManufacturerRAZNO
Catalog number2CCF019629R0001
Type
EAN code7612271471835

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

5kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

5kA

Number of poles (total)

4

Rated impulse withstand voltage Uimp

8kV

Rated insulation voltage Ui

1500V

Rated voltage

1500V

Number of protected poles

4

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

5kA

Pollution degree

2

Voltage type

DC

Built-in depth

111mm

Additional equipment possible

No

Over voltage category

3

Concurrently switching neutral conductor

No

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

5kA

Rated current

50A

Frequency

0 - 0Hz

Ambient temperature during operating

-25 - 60°C

Suitable for flush-mounted installation

No

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 - 70mm²

Connectable conductor cross section solid-core

0 - 50mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCF019629R0001 | S804PV-SP50 HIGH PERFORMANCE MCB

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

5kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

5kA

Number of poles (total)

4

Rated impulse withstand voltage Uimp

8kV

Rated insulation voltage Ui

1500V

Rated voltage

1500V

Number of protected poles

4

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

5kA

Pollution degree

2

Voltage type

DC

Built-in depth

111mm

Additional equipment possible

Over voltage category

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

5kA

Rated current

50A

Frequency

0 .. 0Hz

Ambient temperature during operating

-25 .. 60°C

Suitable for flush-mounted installation

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 70mm²

Connectable conductor cross section solid-core

0 .. 50mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.