Technical specifications

Voltage typeAC
Rated current16A
Built-in depth75mm
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Rated voltage400V
Release characteristicC
Current limiting class3
Pollution degree3
Width in number of modular spacings3
Degree of protection (IP)IP20
Number of protected poles3
Power loss6.6W
Concurrently switching neutral conductorNo
Explosion-proofNo
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0.75 - 25mm²
Rated impulse withstand voltage Uimp4kV
Number of poles (total)3
Flush-mounted installationNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Connectable conductor cross section multi-wiredmm²
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS573001R0164 | S403M-C16 MINIATURE CIRCUIT BREAKER

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated current

16A

Built-in depth

75mm

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Rated voltage

400V

Release characteristic

C

Current limiting class

3

Pollution degree

3

Width in number of modular spacings

3

Degree of protection (IP)

IP20

Number of protected poles

3

Power loss

6.6W

Concurrently switching neutral conductor

Explosion-proof

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0.75 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

3

Flush-mounted installation

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Connectable conductor cross section multi-wired

mm²

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Over voltage category

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.