Aleta.hr
Main Product Image

2CCS573103R8377 | S403M-K6NP MINIATURE CIRCUIT BREAKER

Code: 1858298

ManufacturerABB
Catalog number2CCS573103R8377
EAN code7612270104147

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth75mm
Current limiting class3
Voltage typeAC
Rated current6A
Rated insulation voltage Ui440V
Release characteristicK
Rated voltage400V
Frequency50 - 60Hz
Pollution degree3
Degree of protection (IP)IP20
Explosion-proofNo
Over voltage category3
Width in number of modular spacings4
Power loss5.6W
Connectable conductor cross section multi-wiredmm²
Connectable conductor cross section solid-core0.75 - 25mm²
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Ambient temperature during operating-25 - 55°C
Concurrently switching neutral conductorYes
Number of protected poles3
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS573103R8377 | S403M-K6NP MINIATURE CIRCUIT BREAKER

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

75mm

Current limiting class

3

Voltage type

AC

Rated current

6A

Rated insulation voltage Ui

440V

Release characteristic

K

Rated voltage

400V

Frequency

50 .. 60Hz

Pollution degree

3

Degree of protection (IP)

IP20

Explosion-proof

Over voltage category

3

Width in number of modular spacings

4

Power loss

5.6W

Connectable conductor cross section multi-wired

mm²

Connectable conductor cross section solid-core

0.75 .. 25mm²

Suitable for flush-mounted installation

Additional equipment possible

Ambient temperature during operating

-25 .. 55°C

Concurrently switching neutral conductor

Number of protected poles

3

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.