Aleta.hr
Main Product Image

2CCS861002R0064 | S801S-C6-R HIGH PERFORMANCE MCB

Code: 1858346

ManufacturerABB
Catalog number2CCS861002R0064
EAN code7612271408305

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Voltage typeAC
Rated insulation voltage Ui690V
Power loss1.8W
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Explosion-proofNo
Number of poles (total)1
Connectable conductor cross section multi-wired0 - 70mm²
Connectable conductor cross section solid-core0 - 50mm²
Pollution degree3
Flush-mounted installationNo
Additional equipment possibleYes
Current limiting class3
Width in number of modular spacings1
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Release characteristicC
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Over voltage category3
Number of protected poles1
Degree of protection (IP)IP20
Rated current6A
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861002R0064 | S801S-C6-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Voltage type

AC

Rated insulation voltage Ui

690V

Power loss

1.8W

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Explosion-proof

Number of poles (total)

1

Connectable conductor cross section multi-wired

0 .. 70mm²

Connectable conductor cross section solid-core

0 .. 50mm²

Pollution degree

3

Flush-mounted installation

Additional equipment possible

Current limiting class

3

Width in number of modular spacings

1

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Release characteristic

C

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Over voltage category

3

Number of protected poles

1

Degree of protection (IP)

IP20

Rated current

6A

Rated impulse withstand voltage Uimp

8kV