Technical specifications

Built-in depth82.5mm
Voltage typeAC
Rated insulation voltage Ui690V
Current limiting class3
Frequency50 - 60Hz
Power loss1.7W
Rated current8A
Over voltage category3
Release characteristicB
Rated voltage400V
Degree of protection (IP)IP20
Number of protected poles1
Pollution degree3
Width in number of modular spacings1
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Explosion-proofNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Additional equipment possibleYes
Number of poles (total)1
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861002R0085 | S801S-B8-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Voltage type

AC

Rated insulation voltage Ui

690V

Current limiting class

3

Frequency

50 .. 60Hz

Power loss

1.7W

Rated current

8A

Over voltage category

3

Release characteristic

B

Rated voltage

400V

Degree of protection (IP)

IP20

Number of protected poles

1

Pollution degree

3

Width in number of modular spacings

1

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Explosion-proof

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Additional equipment possible

Number of poles (total)

1

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 70mm²