Aleta.hr
Main Product Image

2CCS861002R0105 | S801S-B10-R HIGH PERFORMANCE MCB

Code: 1858354

ManufacturerABB
Catalog number2CCS861002R0105
EAN code7612271209636

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Frequency50 - 60Hz
Release characteristicB
Rated voltage400V
Rated current10A
Built-in depth82.5mm
Width in number of modular spacings1
Explosion-proofNo
Rated insulation voltage Ui690V
Pollution degree3
Number of protected poles1
Over voltage category3
Power loss1.5W
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 70mm²
Number of poles (total)1
Connectable conductor cross section solid-core0 - 50mm²
Current limiting class3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861002R0105 | S801S-B10-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Frequency

50 .. 60Hz

Release characteristic

B

Rated voltage

400V

Rated current

10A

Built-in depth

82.5mm

Width in number of modular spacings

1

Explosion-proof

Rated insulation voltage Ui

690V

Pollution degree

3

Number of protected poles

1

Over voltage category

3

Power loss

1.5W

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 70mm²

Number of poles (total)

1

Connectable conductor cross section solid-core

0 .. 50mm²

Current limiting class

3

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.