Aleta.hr
Main Product Image

2CCS861002R0401 | S801S-D40-R HIGH PERFORMANCE MCB

Code: 1858370

ManufacturerABB
Catalog number2CCS861002R0401
EAN code7612271207304

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Rated current40A
Degree of protection (IP)IP20
Over voltage category3
Concurrently switching neutral conductorNo
Width in number of modular spacings1
Suitable for flush-mounted installationNo
Pollution degree3
Number of protected poles1
Built-in depth82.5mm
Frequency50 - 60Hz
Rated voltage400V
Rated insulation voltage Ui690V
Current limiting class3
Power loss4.3W
Explosion-proofNo
Release characteristicD
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 70mm²
Rated impulse withstand voltage Uimp8kV
Number of poles (total)1
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Connectable conductor cross section solid-core0 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861002R0401 | S801S-D40-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated current

40A

Degree of protection (IP)

IP20

Over voltage category

3

Concurrently switching neutral conductor

Width in number of modular spacings

1

Suitable for flush-mounted installation

Pollution degree

3

Number of protected poles

1

Built-in depth

82.5mm

Frequency

50 .. 60Hz

Rated voltage

400V

Rated insulation voltage Ui

690V

Current limiting class

3

Power loss

4.3W

Explosion-proof

Release characteristic

D

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 70mm²

Rated impulse withstand voltage Uimp

8kV

Number of poles (total)

1

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Connectable conductor cross section solid-core

0 .. 50mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.