Aleta.hr
Main Product Image

2CCS861002R0405 | S801S-B40-R HIGH PERFORMANCE MCB

Code: 1858372

ManufacturerABB
Catalog number2CCS861002R0405
EAN code7612271206826

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Release characteristicB
Rated current40A
Rated voltage400V
Voltage typeAC
Built-in depth82.5mm
Width in number of modular spacings1
Current limiting class3
Power loss3.7W
Explosion-proofNo
Rated insulation voltage Ui690V
Pollution degree3
Connectable conductor cross section solid-core0 - 50mm²
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Flush-mounted installationNo
Number of protected poles1
Connectable conductor cross section multi-wired0 - 70mm²
Number of poles (total)1
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS861002R0405 | S801S-B40-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Release characteristic

B

Rated current

40A

Rated voltage

400V

Voltage type

AC

Built-in depth

82.5mm

Width in number of modular spacings

1

Current limiting class

3

Power loss

3.7W

Explosion-proof

Rated insulation voltage Ui

690V

Pollution degree

3

Connectable conductor cross section solid-core

0 .. 50mm²

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Flush-mounted installation

Number of protected poles

1

Connectable conductor cross section multi-wired

0 .. 70mm²

Number of poles (total)

1

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.