Technical specifications

Rated insulation voltage Ui690V
Rated current10A
Width in number of modular spacings2
Built-in depth82.5mm
Voltage typeAC/DC
Frequency50 - 60Hz
Power loss3W
Rated voltage400V
Degree of protection (IP)IP20
Release characteristicC
Over voltage category4
Explosion-proofNo
Pollution degree3
Current limiting class3
Number of protected poles2
Connectable conductor cross section multi-wired0 - 70mm²
Connectable conductor cross section solid-core0 - 50mm²
Suitable for flush-mounted installationNo
Number of poles (total)2
Flush-mounted installationNo
Additional equipment possibleNo
Ambient temperature during operating-25 - 60°C
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V40kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V40kA
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862002R0104 | S802S-C10-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

690V

Rated current

10A

Width in number of modular spacings

2

Built-in depth

82.5mm

Voltage type

AC/DC

Frequency

50 .. 60Hz

Power loss

3W

Rated voltage

400V

Degree of protection (IP)

IP20

Release characteristic

C

Over voltage category

4

Explosion-proof

Pollution degree

3

Current limiting class

3

Number of protected poles

2

Connectable conductor cross section multi-wired

0 .. 70mm²

Connectable conductor cross section solid-core

0 .. 50mm²

Suitable for flush-mounted installation

Number of poles (total)

2

Flush-mounted installation

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

40kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

40kA

Concurrently switching neutral conductor