2CCS862002R0325 | S802S-B32-R HIGH PERFORMANCE MCB

Code: 1858453

ManufacturerABB
Catalog number2CCS862002R0325
EAN code7612271209742

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Rated voltage400V
Rated current32A
Built-in depth82.5mm
Frequency50 - 60Hz
Rated insulation voltage Ui690V
Current limiting class3
Release characteristicB
Pollution degree3
Explosion-proofNo
Power loss6.4W
Width in number of modular spacings2
Ambient temperature during operating-25 - 60°C
Over voltage category4
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Number of protected poles2
Suitable for flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 70mm²
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp8kV
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Connectable conductor cross section solid-core0 - 50mm²
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V40kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V40kA
Additional equipment possibleNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862002R0325 | S802S-B32-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Rated voltage

400V

Rated current

32A

Built-in depth

82.5mm

Frequency

50 .. 60Hz

Rated insulation voltage Ui

690V

Current limiting class

3

Release characteristic

B

Pollution degree

3

Explosion-proof

Power loss

6.4W

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 60°C

Over voltage category

4

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Number of protected poles

2

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 70mm²

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

8kV

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Connectable conductor cross section solid-core

0 .. 50mm²

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

40kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

40kA

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.