Aleta.hr
Main Product Image

2CCS862002R0404 | S802S-C40-R HIGH PERFORMANCE MCB

Code: 1858455

ManufacturerABB
Catalog number2CCS862002R0404
EAN code7612271207120

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Voltage typeAC
Release characteristicC
Built-in depth82.5mm
Rated insulation voltage Ui690V
Rated current40A
Rated voltage400V
Current limiting class3
Pollution degree3
Over voltage category3
Width in number of modular spacings2
Suitable for flush-mounted installationNo
Number of protected poles2
Explosion-proofNo
Connectable conductor cross section solid-core0 - 50mm²
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0 - 70mm²
Flush-mounted installationNo
Power loss7.4W
Number of poles (total)2
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V40kA
Rated impulse withstand voltage Uimp8kV
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V40kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862002R0404 | S802S-C40-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Voltage type

AC

Release characteristic

C

Built-in depth

82.5mm

Rated insulation voltage Ui

690V

Rated current

40A

Rated voltage

400V

Current limiting class

3

Pollution degree

3

Over voltage category

3

Width in number of modular spacings

2

Suitable for flush-mounted installation

Number of protected poles

2

Explosion-proof

Connectable conductor cross section solid-core

0 .. 50mm²

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 70mm²

Flush-mounted installation

Power loss

7.4W

Number of poles (total)

2

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

40kA

Rated impulse withstand voltage Uimp

8kV

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

40kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.