Aleta.hr
Main Product Image

2CCS862002R0407 | S802S-K8-R HIGH PERFORMANCE MCB

Code: 1858457

ManufacturerABB
Catalog number2CCS862002R0407
EAN code7612271411619

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Voltage typeAC
Frequency50 - 60Hz
Rated current8A
Rated voltage400V
Current limiting class3
Pollution degree3
Explosion-proofNo
Rated insulation voltage Ui690V
Width in number of modular spacings2
Power loss3W
Release characteristicK
Number of protected poles2
Over voltage category3
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Connectable conductor cross section solid-core0 - 50mm²
Suitable for flush-mounted installationNo
Number of poles (total)2
Connectable conductor cross section multi-wired0 - 70mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V40kA
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V40kA
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862002R0407 | S802S-K8-R HIGH PERFORMANCE MCB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Voltage type

AC

Frequency

50 .. 60Hz

Rated current

8A

Rated voltage

400V

Current limiting class

3

Pollution degree

3

Explosion-proof

Rated insulation voltage Ui

690V

Width in number of modular spacings

2

Power loss

3W

Release characteristic

K

Number of protected poles

2

Over voltage category

3

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Connectable conductor cross section solid-core

0 .. 50mm²

Suitable for flush-mounted installation

Number of poles (total)

2

Connectable conductor cross section multi-wired

0 .. 70mm²

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

40kA

Flush-mounted installation

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

40kA

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.