Aleta.hr
Main Product Image

2CCS862002R0841 | S802S-D125-R HIGH PERFORMANCE

Code: 1858482

ManufacturerABB
Catalog number2CCS862002R0841
EAN code7612271207410

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Width in number of modular spacings2
Power loss3.6W
Rated current125A
Explosion-proofNo
Current limiting class3
Degree of protection (IP)IP20
Pollution degree3
Rated insulation voltage Ui690V
Rated voltage400V
Over voltage category3
Voltage typeAC
Frequency50 - 60Hz
Built-in depth82.5mm
Suitable for flush-mounted installationNo
Number of protected poles2
Connectable conductor cross section multi-wired0 - 70mm²
Connectable conductor cross section solid-core0 - 50mm²
Concurrently switching neutral conductorNo
Release characteristicD
Additional equipment possibleYes
Number of poles (total)2
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V40kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V40kA
Ambient temperature during operating-25 - 60°C
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862002R0841 | S802S-D125-R HIGH PERFORMANCE

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Width in number of modular spacings

2

Power loss

3.6W

Rated current

125A

Explosion-proof

Current limiting class

3

Degree of protection (IP)

IP20

Pollution degree

3

Rated insulation voltage Ui

690V

Rated voltage

400V

Over voltage category

3

Voltage type

AC

Frequency

50 .. 60Hz

Built-in depth

82.5mm

Suitable for flush-mounted installation

Number of protected poles

2

Connectable conductor cross section multi-wired

0 .. 70mm²

Connectable conductor cross section solid-core

0 .. 50mm²

Concurrently switching neutral conductor

Release characteristic

D

Additional equipment possible

Number of poles (total)

2

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

40kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

40kA

Ambient temperature during operating

-25 .. 60°C

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.